Log:
Downloads : 16   Arquivo Tamanho: 2 mb   Fabricante : Enviro  
Categoria : Lareiras
@name

With the Drafthood Adaptor correctly installed and wired to the gas control valve. Your Direct Vent Fireplace can be vented like a B-Vent Fireplace. INSTALLATION: WARNING: This Freestanding Drafthood Adaptor must be fitted by a qualified service technician. Step 1 Remove the Drafthood Adaptor from the packaging. Ensure the unit and wire harness are undamaged. If there is damage contact your dealer, distributor, or courier company before starting this installation. Step 2 Install the adaptor so t

Downloads : 0   Arquivo Tamanho: 3 mb   Fabricante : Enviro  
Categoria : Lareiras
@name

Do not pack air spaces with insulation. 2. Set the gas appliance in the desired location. Drop a plumb bob down from the ceiling to the position of the appliance flue exit, and mark the location where the vent will penetrate the ceiling. Drill a small hole at this point. Next, drop a plumb bob from the roof to the hole previously drilled in the ceiling, mark the spot where the vent will penetrate the roof. Determine if ceiling joists, roof rafters, or other framing will obstruct the venting syst

Downloads : 5   Arquivo Tamanho: 2 mb   Fabricante : Enviro  
Categoria : Lareiras
@name

INSTALLATION INSTRUCTIONS: 1. Plan your installation and clearances to combustibles. Decide on a location for the unit that will meet the clearances noted in the venting section, and any or all local code requirements. 2. Set the appliance in the desired location. Determine if any wall studs, electrical wiring, or plumbing pipes are in the way of the venting system as it passes through the exterior wall. The fireplace location should be adjusted if obstructions are found in the wall. 3. Project

Downloads : 3   Arquivo Tamanho: 2 mb   Fabricante : Enviro  
Categoria : Lareiras
@name

14. Attach the vent terminal to the outside of the house using four (4) wood screws provided. 15. Light the appliance and ensure proper operation. OTHER APPROVED VENT PARTS: Table 3: Approved Vent Manufacturers Manufacturer Trade Name Nominal Sizes American Metal Products AmeriVent Direct 4” - 6 5/8” Security Chimneys International LTD Secure Vent 4” - 6 5/8” Selkirk Metalbestos Direct-Temp 4” - 6 5/8” Simpson Dura-Vent Direct Vent GS 4” - 6 5/8” The Retreat fireplace has been tested and certifi

Downloads : 2   Arquivo Tamanho: 3 mb   Fabricante : Enviro  
Categoria : Lareiras
@name

PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE PELLET STOVE EF3 Freestanding, Fireplace Insert, and Built-In Heater OWNER’S MANUAL Contact your building or fire officials about restrictions and installation inspection requirements in your area. PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. EF-118 Table of Contents Introduction..................

Downloads : 2   Arquivo Tamanho: 845 kb   Fabricante : Enviro  
Categoria : Lareiras
@name

UPON CONNECTION, MARK APPROPRIATE FUEL TYPE ON RATING LABEL LOCATED ON THE INSIDE OF THE RIGHT HAND SIDE PANEL. Manifold Pressure Tap. Inlet Pressure Tap. Millivolt Terminals Pilot Adjustment screw. "HI-LOW" Burner Gas Knob. Pilot "ON-OFF" Gas Knob. Text Box: ORIFICE SIZES, PRESSURE AND BTU’S The appliance and its shutoff valves must be disconnected from the gas supply piping system during any pressure testing where the pressure exceeds 1/2 PSIG (3.45 kPa) or damage will occur to the valve. The

Downloads : 0   Arquivo Tamanho: 566 kb   Fabricante : Enviro  
Categoria : Lareiras
@name

• Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. WARNING If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A qualified installer, service agency or the gas supplier must perform installation and service. I

Downloads : 8   Arquivo Tamanho: 1 mb   Fabricante : Enviro  
Categoria : Lareiras
@name

May also be vented through a conventional chimney using a chimney liner kit. This appliance has been tested and approved for installations from 0 feet to 2000 feet (610 m) above sea level. In the USA: The appliance may be installed at higher altitudes. Please refer to your American Gas Association guidelines which state: the sea level rated input of Gas Designed Appliances installed at elevations above 2000 feet (610 m) is to be reduced 4% for each 1000 feet (305 m) above sea level. Refer also t

Downloads : 0   Arquivo Tamanho: 2 mb   Fabricante : Enviro  
Categoria : Lareiras
@name

Initial Installation QUALIFIED INSTALLERS ONLY Figure 33: Multi-Story Vent Pipe Installation. Figure 34: Cathedral Ceiling Support Box Leveling. Figure 35: Cathedral Ceiling Support Box Installation. 2 Initial Installation QUALIFIED INSTALLERS ONLY VENTING INTO A CLASS ‘A’ CHIMNEY: This model is also certified and tested to vent into CLASS ‘A’ wood stove chimneys. Place the freestanding direct vent appliance in the desired location. Use a conversion kit from Simpson Duravent (931, 932, or 933),

Downloads : 48   Arquivo Tamanho: 2 mb   Fabricante : Enviro  
Categoria : Lareiras
@name

123/8" (315mm) 55/16" (135mm) 45o3415/16" (887mm) 401/4" (1022mm) Figure 17. Dimensions for Framing the Firebox. Table 3. Inlet Placement Dimensions, refer to Figure 1. Side Inlet: Gas Electrical Distance back 63/16” 15.8 cm 81.2 21.5 cm Distance up 15.8” 4.1 cm 111/16” 4.3 cm Bottom Inlet: Gas Electrical Distance back 59/16” 14.1 cm 811/16” 22.0 cm Distance from side 37.8” 9.8 cm 43.4” 12.1 cm Figure 18. Dimensions for Top Framing the Firebox. 1 The gas line, 3.8 inch NPT, can be brought to eit





categorias