Log:
Sort : Nome ↑   Downloads   Avaliação   Tamanho ↑  
Downloads : 5   Arquivo Tamanho: 5 mb   Fabricante : Enviro  
Categoria : Lareiras
@name

Use a non-abrasive cleaner and NEVER clean the glass while it is hot. AERATION ADJUSTMENT The air shutter can be adjusted by moving the adjusting wire up or down. The wire is accessed through the bottom louver opening. Open the air shutter for a blue flame or close for a more yellow flame. The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude. This adjustment is performed by the gas fitter. Minimum Air Shutter Opening: 5/16" Natural Gas 3/8" Pro

Downloads : 5   Arquivo Tamanho: 3 mb   Fabricante : Enviro  
Categoria : Lareiras
@name

CLEARANCES TO COMBUSTIBLES: A. Sidewall to unit 11 inches (27.9 cm) B. Backwall to unit 2.5 inches (6.35 cm) C. Corner to unit 2.5 inches (6.35 cm) D. Ceiling 60 inches above floor (152.4 cm) E. Floor (hard wood and linoleum) 0 inches Note: When installing on a carpeted surfaces a non- combustible hearth pad must be used. Minimum Alcove Dimensions: Width 48 inches (121.9 cm) Height 60 inches (152.4 cm) Depth (max) 24 inches (60.96 cm) CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE

Downloads : 0   Arquivo Tamanho: 3 mb   Fabricante : Enviro  
Categoria : Lareiras
@name

Do not pack air spaces with insulation. 2. Set the gas appliance in the desired location. Drop a plumb bob down from the ceiling to the position of the appliance flue exit, and mark the location where the vent will penetrate the ceiling. Drill a small hole at this point. Next, drop a plumb bob from the roof to the hole previously drilled in the ceiling, mark the spot where the vent will penetrate the roof. Determine if ceiling joists, roof rafters, or other framing will obstruct the venting syst

Downloads : 0   Arquivo Tamanho: 2 mb   Fabricante : Enviro  
Categoria : Lareiras
@name

Temperature Sensor Clinking when it senses to turn the blower on or off. Pilot Flame Quiet whisper while the pilot flame in on. Blower / Fan Air movement that increase and decreases with the speed of the blower. The blower is pushing the heat from the fireplace into the room. Gas Control Valve Dull click when turning on or off, this is the valve opening and closing. .............. Figure 6. Fan control. Pullouttheventuriadjustmenttoincreaseprimaryairattheventuritube. Pushintheventuriadjustmentto

Downloads : 2   Arquivo Tamanho: 845 kb   Fabricante : Enviro  
Categoria : Lareiras
@name

UPON CONNECTION, MARK APPROPRIATE FUEL TYPE ON RATING LABEL LOCATED ON THE INSIDE OF THE RIGHT HAND SIDE PANEL. Manifold Pressure Tap. Inlet Pressure Tap. Millivolt Terminals Pilot Adjustment screw. "HI-LOW" Burner Gas Knob. Pilot "ON-OFF" Gas Knob. Text Box: ORIFICE SIZES, PRESSURE AND BTU’S The appliance and its shutoff valves must be disconnected from the gas supply piping system during any pressure testing where the pressure exceeds 1/2 PSIG (3.45 kPa) or damage will occur to the valve. The

Downloads : 2   Arquivo Tamanho: 3 mb   Fabricante : Enviro  
Categoria : Lareiras
@name

PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE PELLET STOVE EF3 Freestanding, Fireplace Insert, and Built-In Heater OWNER’S MANUAL Contact your building or fire officials about restrictions and installation inspection requirements in your area. PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. EF-118 Table of Contents Introduction..................

Downloads : 48   Arquivo Tamanho: 2 mb   Fabricante : Enviro  
Categoria : Lareiras
@name

123/8" (315mm) 55/16" (135mm) 45o3415/16" (887mm) 401/4" (1022mm) Figure 17. Dimensions for Framing the Firebox. Table 3. Inlet Placement Dimensions, refer to Figure 1. Side Inlet: Gas Electrical Distance back 63/16” 15.8 cm 81.2 21.5 cm Distance up 15.8” 4.1 cm 111/16” 4.3 cm Bottom Inlet: Gas Electrical Distance back 59/16” 14.1 cm 811/16” 22.0 cm Distance from side 37.8” 9.8 cm 43.4” 12.1 cm Figure 18. Dimensions for Top Framing the Firebox. 1 The gas line, 3.8 inch NPT, can be brought to eit

Downloads : 0   Arquivo Tamanho: 542 kb   Fabricante : Enviro  
Categoria : Lareiras
@name

If practical, it is best to locate the appliance to permit the use of shorter horizontals and fewer elbows. -Two 90° elbow, maximum total horizontal length of 20 ft (6m). -Three 90° elbow, maximum total horizontal length of 13 ft (3.8m). -Four 90° elbow, maximum total horizontal length of 6 ft (1.9m). -Five 90° elbow, maximum total horizontal length of 0 ft (0m). If 45° elbows are used, one 90° elbow is equivalent to two 45° elbows. Venting rise should be a minimum of 1 ft (.31m). from the top o

Downloads : 4   Arquivo Tamanho: 2 mb   Fabricante : Enviro  
Categoria : Lareiras
@name

PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Haven DIRECT VENT FIREPLACE BY: SHERWOOD INDUSTRIES LTD OWNER’S MANUAL WHAT TO DO IF YOU SMELL GAS • Open windows/extinguish any open flame. • Do not try to light any appliance. • Do not touch any electrical switch or use any phone in your building. • Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. This appliance may be instal

Downloads : 0   Arquivo Tamanho: 2 mb   Fabricante : Enviro  
Categoria : Lareiras
@name

Initial Installation QUALIFIED INSTALLERS ONLY Figure 33: Multi-Story Vent Pipe Installation. Figure 34: Cathedral Ceiling Support Box Leveling. Figure 35: Cathedral Ceiling Support Box Installation. 2 Initial Installation QUALIFIED INSTALLERS ONLY VENTING INTO A CLASS ‘A’ CHIMNEY: This model is also certified and tested to vent into CLASS ‘A’ wood stove chimneys. Place the freestanding direct vent appliance in the desired location. Use a conversion kit from Simpson Duravent (931, 932, or 933),





categorias