Log:
Sort : Nome ↑   Downloads   Avaliação   Tamanho ↑  
Downloads : 5   Arquivo Tamanho: 5 mb   Fabricante : Empire Comfort Systems  
Categoria : Lareiras
@name

Gas supply piping should also be planned at this time. A gas shut off must be in this line. 45° 6” 3” MAX. PERPENDICULAR SIDE WALL FRONT FACE (SIDE) FIREBOX (TOP VIEW) COMBUSTIBLE MATERIALS ALLOWED IN SHADED AREAS FIREBOX STAND OFF FINISH WITH TRIM KIT OR NON-COMBUSTIBLE MATERIAL AS DESIRED. COMBUSTIBLE FINISHED WALL 2 X 4 OR MANTEL HEADER MANTEL HOOD 13” 10” 12” MAX 42” MIN. (CEILING TO TOP OF HOOD) 11 1/2” MIN. FIREBOX FACE 84” MIN. (CEILING TO FLOOR) CEILING COMBUSTIBLES ALLOWED 3/8” COMBUSTI

Downloads : 4   Arquivo Tamanho: 4 mb   Fabricante : Empire Comfort Systems  
Categoria : Lareiras
@name

See Figure B. Maintain equal distance between spring spacers. 3. Remove the 6-." dia. Vent collar from the fireplace. Replace this collar with the 7" dia. Flex Vent adapter collar provided with the vent kit. 4. Slide the Flex Vent flue pipe into the Outer Flex Vent pipe. 5. Install the Wall Firestop/Thimble assembly as required through the wall. Refer to the venting charts in the fireplace manual to determine the proper height and size of the vent opening. The minimum opening should be 9" wide b

Downloads : 8   Arquivo Tamanho: 5 mb   Fabricante : Empire Comfort Systems  
Categoria : Lareiras
@name

3. Run the other end of the duct through the exterior wall cutout. 4. From the outside of the building, connect the duct to the collar on the outside air vent assembly with band clamp or screws to secure. 5. Mate the outside rain cap hood over the air vent, seal with caulk as necessary, then secure with screws provided to the exterior wall surface. See Figure 22 and 23. 6. Figure 24 illustrates the various options for installation of the air duct run possibilities. OUTSIDE HOOD 4” DIA. AIR DUCT

Downloads : 1   Arquivo Tamanho: 4 mb   Fabricante : Empire Comfort Systems  
Categoria : Lareiras
@name

Insert natural gas front burner bushing into throat (Venturi) of front burner. See Figure 45. 11. Replace front burner with one (1) screw from Step 8. 12. Remove rear burner (one (1) screw). 13. Use 3/8” socket or wrench to remove propane gas rear burner orifice marked 1.45 from orifice fitting. Replace with natural gas rear burner orifice marked 43 into orifice fitting. 14. Replace rear burner with one (1) screw from Step 12. 15. Connect caps and plugs on flame sensor and hot surface ignitor. 1

Downloads : 1   Arquivo Tamanho: 4 mb   Fabricante : Empire Comfort Systems  
Categoria : Lareiras
@name

The maximum allowable reduction in manifold pressure for Natural gas shall be from 3.5” w.c. (.872 kPa) to 2.8” w.c. (.697 kPa). The maximum allowable reduction in manifold pressure for Propane (LP) gas shall be from 10.0” w.c. (2.49 kPa) to 8.0” w.c. (1.99 kPa). For Canadian high altitude applications, this appliance is suitable for installation at elevations between 0 feet (0 m) and 4,500 feet (1,372 m) without change. Canada: This appliance is NOT to be installed in Canada. 22618-17-0308 Page

Downloads : 1   Arquivo Tamanho: 4 mb   Fabricante : Empire Comfort Systems  
Categoria : Lareiras
@name

Figure 6 Gas Supply Pressure (inches w.c.) Minimum Normal Maximum Natural Gas 4.5" 7.0" 14.0" LP (Propane) 10.8" 11.0" 14.0" Manifold Pressure (inches w.c.) Normal (HI) Natural Gas 3.5" LP (Propane) 10.0" Page 8 19400-3-0406 19400-3-0406 Page 9 FROM FRONT OF APPLIANCE TO GAS LINE HOLE 3 .” GAS LINE HOLE BVD34 SERIES - 10” BVD,P (36,42) - 13 .” Figure 7 BURNER ASSEMBLY REAR TAB (BURNER BASE) LOCATIONS FLEXIBLE GAS CONNECTOR GAS SUPPLY LINE FIREBOX BOTTOM CUTOUT ACCESS SLIDING VALVE ACCESS COVER P

Downloads : 1   Arquivo Tamanho: 4 mb   Fabricante : Empire Comfort Systems  
Categoria : Lareiras
@name

It will be soft during this paint-curing phase. Once cured it will not be soft again. 3. The paint finish of the heater should not be cleaned with any caustic or abrasive cleaning solutions. 4. Any damage to painted surface should be repaired with special touch paint available from your Mantis Dealer. MAINTENANCE Note: Your appliance should be inspected, serviced and checked annually by a qualified service person to ensure that your appliance is operating safe and efficiently. Should you detect

Downloads : 1   Arquivo Tamanho: 3 mb   Fabricante : Empire Comfort Systems  
Categoria : Lareiras
@name

Breastboard will rest on fireplace top and in front of nailing flange. Attention: Placing the breastboard in front of nailing flange will secure the fireplace. 6. Placeleftmantelsideagainstbase.Insertdowelsinbreastboard into left mantel side. 7. Use four (4) pre-drilled screw holes on back of breastboard to secure breastboard to mantel sides with four (4) Phillips wood screws. 8. Place mantel top onto mantel. 9. Installation of fireplace into mantel is completed. Installation of Trim 1. Lower bo

Downloads : 0   Arquivo Tamanho: 4 mb   Fabricante : Empire Comfort Systems  
Categoria : Lareiras
@name

Then take the same immediate action recommended above for the occasion when you do detect the odorized LP-Gas. • If you experience a complete “gas out,” (the container is under no vapor pressure), turn the tank valve off immediately. If the container valve is left on, the container may draw in some air through openings such as pilot light orifices. If this occurs, some new internal rusting could occur. If the valve is left open, then treat the container as a new tank. Always be sure your contain

Downloads : 18   Arquivo Tamanho: 2 mb   Fabricante : Empire Comfort Systems  
Categoria : Lareiras
@name

This should consist of a vertical length of pipe tee connected into the gas line that is capped on the bottom in which condensation and foreign particles may collect. The use of the following gas connectors is recommended: — ANS Z21.24 Appliance Connectors of Corrugated Metal Tubing and Fittings — ANS Z21.45 Assembled Flexible Appliance Connectors of Other Than All-Metal Construction The above connectors may be used if acceptable by the authority having jurisdiction The state of Massachusetts re