Log:
Assessments - 1, GPA: 4 ( )

Instruções de Operação Friedrich, Modelo 230 VoltsUE12

Fabricante : Friedrich
Arquivo Tamanho: 1.98 mb
Arquivo Nome :
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


This is not covered under the terms of the FRIEDRICH warranty. CAUTION • Pick a location which will allow the conditioned air to blow into the area you want. Good installation with special attention to the proper position of the unit will lessen the chance that service will be needed. ITEMS IN INSTALLATION HARDWARE You may not need all parts in the kit. Discard unused parts ITEM DIMENSIONS(inches) Qty. Plastic grille 263/4 x 161/2 1 Horizontal Insulation Strips 13/8 x 5/8 x 273/16 1 13/8 x 13/8 x 273/16 1 Around Insulation Strips 13/8 x 3/4 x 611/2 1 13/8 x 13/8 x 611/2 1 Support Block 13/4 x 13/8 x 45/16 2 Baffle 14 x 41/2 x 1/8 1 Shim 13 x 1 x 3/4 2 Trim Frame 2 Washer Screw 4 Nuts(Plastic) 4 HOW TO INSTALL 1 Before installing the unit, identify the existing wall sleeve from the list below. Brand Wall Sleeve Dimensions (inches) Width Height Depth White-Westinghouse Frigidaire Carrier (52F series) 25-1/2 15-1/4 16, 17-1/2 or 22 General Electric /Hotpoint 26 15-5/8 16-7/8 Whirlpool 25-7/8 16-1/2 17-1/8 or 23 Fedders/Emerson Friedrich WSC 27 16-3/4 16-3/4 or 19-3/4 FRIEDRICH USC 25-7/8 15-17/32 16-23/32 Emerson/Fedders 26-3/4 15-3/4 15 Carrier (51S Series) 25-3/4 16-7/8 18-5/8 NOTE: All wall sleeves used to mount the new Air Conditioner must be in sound structural condition and have a rear grille that securely attaches to sleeve, or rear flange that serves as a stop for the Air Conditioner. Remove old air conditioner from existing wall sleeve. 2 3 4 5 Clean the interior of an existing sleeve. (Do not disturb seals or gaskets.) Wall sleeve must be securely fastened in wall before installing the air conditioner. Use the nails or screws through sleeve into wall, if needed. Repaint sleeve if needed. Prepare the wall sleeve for installation of the unit. If you plan to use your existing wall sleeve, and it is not FRIEDRICH, use procedure B or C below. Procedure Brand Depth(inches) A(page 13) FRIEDRICH USC 16-23/32 B (pages 14~15) White-Westinghouse Frigidaire Carrier (52F series) 16, 17-1/2 or 22 General Electric /Hotpoint 16-7/8 Whirlpool 17-1/8 or 23 Carrier (51S series) 18-5/8 C (pages 16~17) Fedders/Emerson Friedrich WSC 16-3/4 or 19-3/4 Emerson/Fedders 15 6 Install new unit into wall sleeve. CAUTION: When installation is complete, replacement unit MUST have a downward-rear slope as shown below. 1/4" Wall Sleeve FRONT UNIT FIG. 3 12 4 5 Install the new unit into the wall sleeve. PROCEDURE A If you are using the new sleeve supplied with To assemble trim, snap the tab of each piece your unit, skip to step 3. Otherwise, install the into the slot of the other piece as shown below. plastic grille from the kit. Cut the plastic grille to Slide trim over the front of the air conditioner 25-1/2" wide and 15-1/4" high. Place the until trim is flush with sleeve as shown below. plastic grille to the inside of the wall sleeve at the rear flange. Wall Trim (2 ea) FIG. 7 FIG. 4 2 Fasten the 4 washer screws to secure the grille to the wall sleeve. If you need plastic nuts to mount plastic grille to the inside of the wall sleeve, there are plastic nuts in the installation kit. The nuts are installed from the inside of the sleeve and are pressed into the square holes of the rear flanges. FIG. 5 or Features and Installation • Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit. • When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils. • Make sure air conditioner does not fall during removal. CAUTION 3 Remove the backing from the Horizontal Insulation strip 13/8" x 5/8" x 27 3/16" and attach that to the inside bottom of the sleeve as shown below. Remove the backing from the Around Insulation strip 13/8" x 3/4" x 611/2" and attach that to the inside front of the sleeve as shown below. Around Insulation Horizontal Insulation FIG. 6 13 PROCEDURE B 1 Redirect the louvers at the back of the wall sleeve to 60° angle as shown in the FIG 8. The use of pliers is recommended. Rear Louvers (Top View) 60° 60° 7 5/16 " FIG. 8 If the wall sleeve already has a rear grille, skip to step 4. If the wall sleeve does not have a rear grille or louvered panel, install the plastic grille from the kit. Cut the plastic grille to 25-1/2" wide and 15-1/4" high or to the sleeve dimensions. Place the plastic grille to the inside of the wall sleeve at the rear flange. 4 Remove the backing from the Horizontal Insulation strip 13/8" x 5/8" x 273/16" and attach that to the inside bottom of the sleeve as shown below. Remove the backing from the Around Insulation strip 13/8" x 3/4" x 611/2" and attach that to the inside front of the sleeve as shown below. Around Insulation Horizontal Insulation FIG. 11 5 If the depth of your existing wall sleeve is less than or equal to 18", skip to step 7. Otherwise, cut the baffles and the support blocks accordi...

Este manual também é adequado para os modelos :
Aparelhos de ar condicionado - 115 Volts US08 (1.98 mb)
Aparelhos de ar condicionado - 230 Volts US10 (1.98 mb)
Aparelhos de ar condicionado - 230 VoltsUE10 (1.98 mb)
Aparelhos de ar condicionado - 230 VoltsUS12 (1.98 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias