6) Repeat steps 4 and 5 for each digit. a. After pressing ENTER on the fourth digit, you will immediately return to the ENTER SECURITY CODE? screen. 7) You will know you entered the code correctly if the letter in the lower left corner reads M. Refer to Machine Operation and Programming Security Levels on page 15 for more details on other letters that may appear. a. If it does not match, repeat steps 3 through 7. b. If it does match, continue to step 8. 8) Press the UP or DOWN keys repeatedly un
Upper arm nozzles point downward, and lower arm nozzles point upward. Arms in the prewash chamber each have two tubes (the slightly longer arm goes below). The arms with five tubes fit in the upper brackets, and the arms with four tubes fit in the lower brackets. To install arms, slide manifolds on the guides toward the rear of the machine (Fig. 26). Then latch arms in place (Fig. 27). Fig. 25 Fig. 26 Fig. 27 Replace the pump intake screens, strainer pans, and strainer baskets. Rehang the curtai
C (Mar. 2000) Operation and Care of FT900 SERIES DISHWASHERS SAVE THESE INSTRUCTIONS OPERATION MACHINE PREPARATION — Check before beginning operation. Raise the machine doors and make sure all components are in their proper operating positions. Pump Intake Screens must be put on Strainer Pans must be in place on top of Strainer Baskets must be in place in holders at each pump intake (Fig. 1). each tank (Fig. 2). Strainer Pans (Fig. 3). Fig. 1 Fig. 2 End Caps must be correctly installed at Wash A
2007) TABLE OF CONTENTS OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . 3 Machine Preparation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Tank Filling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Dishwashing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FT-800 SERIES DISHWASHER FOOD EQUIPMENT • Water and energy saving design through reduced water and tank heat usage and automatic pump shut down control through conveyor. • Common water, drain, electric and steam connections. • Exclusive load end flush system. • Built-in integral wiring channel. • Automatic temperature control and positive low-water heater and pump seal protection. • Built-in inherent motor overload protection with manual reset. • Built-in vent ducts—dampers and drip control. • I
FastRack Dishwasher STANDARD FEATURES ¦ Top mounted controls ¦ Stainless steel anti-clogging wash arms ¦ Stainless steel front panel ¦ Stainless steel frame and legs ¦ Automatic fill ¦ Scrap screen and bucket system ¦ Stainless steel pump and impeller ¦ Pump intake screen ¦ Door actuated drain closure ¦ Door interlock switch in all doors ¦ Vent fan control ¦ Convertible hot water or low temp final rinse DIRECTION OF OPERATION . Clockwise, Doors In (L-R) . Clockwise, Doors Out (R-L) . Counter-Clo
PUMP: Centrifugal-type, integral with motor, vertically mounted. Pump capacity is 45 U.S. gallons per minute. MOTOR: Built to Hobart specifications, 1.2 H.P., single phase, furnished for 120/60/1, 120/208(3W)/60/1 or 120/240(3W)/60/1 electrical specification. Factory sealed lubrication. RACKING: Will accommodate most racks from 10" x 20" (half racks) to 20" x 20". Will also accept 16" x 18" cafeteria trays. WASH AND RINSE CYCLE: Completely automatic, controlled by an electrically energized synch
120/60/1 (SR24C model only) . 120/208(3W)/60/1 (SR24H model only) . 120/240(3W)/60/1 (SR24H model only) OPTIONS . Detergent pump - factory installed (chemical sensing module included) MODELS . SR24H – High Temperature Sanitizing . SR24C – Chemical Sanitizing ACCESSORIES - field installed . Detergent and/or rinse agent pump (chemical sensing device suggested) . Chemical sensing device (SR24H only) . Stainless steel top and side panels . Stainless steel base with 6" legs . 17" stainless steel stan
. . . . . . . . 11 Drain Connection(s). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 11 Fill & Final Rinse Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Steam Connection (When Equipped). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Gas Connection (When Equipped). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . 11 Drain Connection(s). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 11 Fill & Final Rinse Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Steam Connection (When Equipped). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Gas Connection (When Equipped). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .