Instruções de Operação Frigidaire, Modelo HDG5300AW

Fabricante : Frigidaire
Arquivo Tamanho: 3.01 mb
Arquivo Nome :
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


The more the dryer is used the more often you should check the exhaust system and vent hood for proper operation. Side and Bottom Exhaust For your convenience, your dryer can be exhausted through the side or the bottom. If you need to change the exhaust on the dryer to the side or the bottom of the cabinet, you will need to order the exhaust kit from your Haier dealer or call 1- 800-313-8495 RECOMMENDED MAXIMUM Exhaust Hood Types Recommended Use only for short run installations /■ — -H" ¡10.LT-Il ■T DIA. r>\ ay (6 Jh cm) No. of 90° elbows Rigid Metal Rigid Metal 0 90 ft. 60 ft. 1 60 ft. 45 ft. 2 45 ft. 35 ft. 3 35 ft. 25 ft. The total length of flexible metal duct shall not exceed 94 inches. 8 English GAS SUPPLY REQUIREMENTS Replace copper connecting pipe that is not plastic coated. Stainless steel or plastic-coated brass MUST be used. 1. I nstallation MUST conform with local codes. In the absence of local codes, installation must conform with the National Fuel Gas Code, ANSI Z223.1 (latest edition) or in Canada, the current CAN/CGA B149.1l 2. The gas supply line should be 1/2 inch (1.27cm) pipe. 3. I f codes allow, flexible metal tubing may be used to connect your dryer to the gas supply line. The tubing MUST be constructed of stainless steel or plastic-coated brass. 4. The gas supply line MUST have an individual manual shutoff valve installed within 6 feet (183cm) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1/NFPA 54. In Canada, an individual manual shut-off valve MUST be installed in accordance with the B149.1, Natural Gas and Propane Installation Code. 5. A 1/8 inch (0.32cm) N.P.T. plugged tapping, accessible for test gauge connection, MUST be installed immediately upstream of the gas supply connection to the dryer. 6. The dryer MUST be disconnected from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures in excess of 1/2 psig (3.45kPa). 7. The dryer MUST be isolated from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.45 kPa). A WARNING 9 English LOCATION OF YOUR DRYER Do Not Install Your Dryer: 1. In an area exposed to dripping water or outside weather conditions. 2. I n an area where it will come in contact with curtains, thick carpet, or anything that will obstruct the flow of combustion and ventilation air. 3. On carpet, floor must be solid with a maximum slope of linch (2.54 cm). Any floor unevenness should be corrected with leveling legs located on the bottom of the dryer. Installation in Alcove or Closet: 1. DO NOT install your dryer in a closet with a solid door. 2. A dryer installed in a bedroom, bathroom, alcove or closet MUST be exhausted outdoors. 3. No other fuel burning appliance shall be installed in the same closet as the gas dryer. 4. Refer to the images on this page to ensure the installation provides the minim...

Este manual também é adequado para os modelos :
Secadores - CHDE5000AW (3.01 mb)
Secadores - CHDE5300AW (3.01 mb)
Secadores - HDE5000AW (3.01 mb)
Secadores - CHDE5000AW (3.01 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias