Log:
Assessments - 3, GPA: 3.3 ( )

Instruções de Operação Aube Technologies, Modelo 44668

Fabricante : Aube Technologies
Arquivo Tamanho: 3.29 mb
Arquivo Nome :
Língua de Ensino: enes
Ir para baixar



Facilidade de uso


Likewise, the thermostat will automatically change to heat mode and turn on heat when the room temperature falls below 68°F. Even when in the “Auto” position, Cool Mode and Heat Mode still have to be programmed separately to allow for the “Set Back” periods. Home Today This Hunter patented feature allows you to quickly and temporarily override your energy saving program setting on days when you are normally away from home with one key press. ¦ Press to enter the Home Today override. The highest program temperature for today will be selected from your programs in Heat mode and become the set temperature. (In Cool mode, Home Today will select the lowest program temperature for today to be the set temperature.) ¦ “HOME” will alternate on the display with the day and any other messages. ¦ When pressed during the first or second program of the day, Home Today will automatically return to program control at the start of the fourth program of the day. If Home Today is pressed after the start of the third program time of the day, the thermostat will remain in Home Today mode until the first program of the next day. ¦ If Home Today is already active, you may similarly extend it to the first program of the next day by pressing the key again after the start time of the third program. (continued) Home Today (cont.) ¦ If the system is changed between Heat and Cool modes (either manually or by Auto Season Changeover) during the “Home Today” override period, the setpoint temperature will be automatically updated. It will automatically change from the highest heat program setpoint to the lowest cool program setpoint, or from the lowest cool program setpoint to the highest heat program setpoint. ¦ Press to exit Home Today mode before the schedule ending time. “HOME” is no longer displayed on the LCD screen, and the thermostat returns to the current program. ¦ You can manually change the setpoint temperature while in Home Today mode. Refer to the Temporary Manual Override instructions on page 34. Manually changing the set temperature while in Home Today mode will not affect the Home Today ending time. However, the set temperature will not change automatically with a manual or Automatic change between heating and cooling. ¦ You may also press the Home Today key while in Temporary Manual Override. The operation is the same as the previous point above. Energy Monitor The Energy monitor feature measures and stores the amount of time the heating and air conditioning system operates. Usage can be displayed for Today (since 12AM), Yesterday, This Month (up to 30 days), Last Month (last 30 days), and Total (up to 999 Hrs. 59 Min.). By monitoring your energy usage, you see how much the setback periods are saving and you can test program adjustment to save even more. Use tables on pages 20-21. ¦ To review energy usage, press to cycle through Today, Yesterday, [number] Days, Last 30 days, and Total. Press again to return to normal mode, or wait 15 seconds for the display to return to normal mode. You can also return to normal mode at any time by pressing RET CLEAR. ¦ Press and hold for 3 seconds to reset the Energy Monitor’s counters while in Energy Monitor mode. The display will blink, and all counters will be cleared to zero. ret/clear Filter Monitor Your thermostat also keeps a record of the number of hours your filter has been in use. To maximize your system’s performance and energy efficiency, change or clean your filter regularly. ¦ When the total system run time for heat and cool reaches 500 hours, “FILTER” will alternate on the display with the day to remind you to clean or change your system’s filter. “FILTER” will continue to display until the counter is set back to zero. ¦ Press to review total filter usage. After 15 seconds, the display will return to normal mode, or you can hit RET CLEAR to exit immediately. The Filter Monitor will display up to 999 hours and 59 minutes of usage. ¦ To reset the Filter Monitor counter, hold for 3 seconds. The display will blink, and the counter will be reset to zero. filter ret/clear SPAN Settings Stage 1 Your thermostat is set at the factory to cycle at 1°F (0.5°C) above and below the set temperature in Stage 1. (Span = 2.) This setting has been designed to provide a comfortable room temperature under most all conditions. However, if you find your system cycling too fast or too slow, then the Span can be adjusted to modify the cycle time. Refer to the Option Menu Stage 1 Span selection on page 17. Span = 1. This decreases the cycle time by causing y...

Este manual também é adequado para os modelos :
Os termostatos - 44660 (3.29 mb)
Os termostatos - 44008-01 (3.29 mb)
Os termostatos - 44660 (3.29 mb)
Os termostatos - 44668 (3.29 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias