Instruções de Operação FCI Home Appliances, Modelo COGB33061/WH

Fabricante : FCI Home Appliances
Arquivo Tamanho: 2.84 mb
Arquivo Nome :
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


• Join the pressure regulator to the entrance threads of the Gas Manifold with gasket supplied with this appliance. The regulator is marked with a directional arrow indicating correct direction of gas flow. Ensure the appliance regulator is installed with the arrow pointing toward the gas manifold entrance and make sure the top of the regulator is facing towards the cabinet front, easily accessible through the cabinet doors. • Connect a manual shut-off valve to the gas supply in an accessible location for turning on or shutting off gas to the appliance. • Install a coupling between the regulator and the shutoff valve to complete the connection. • Assure all pipe joint connections are gas tight. • Check alignment of valves after connecting the cooktop to the gas supply to be sure the manifold pipe has not been moved. A misalignment could cause the valve knob stem to rub on the control panel, resulting in a gas leak at the valve. If a oven is to be installed below this appliance connect gas supply line as shown in figure. 11 consider the below cabinet clearance. TO CENTER OF 2" DIA. HOLE FROM COUNTERTOP 4-25/32" (12.5 cm) 2" DIA. HOLE (20-7/8" FROM FRONT OF COUNTERTOP TO HOLE CENTER 90° STREET ELBOW CABINET SIDES CABINET SIDES 011 Figure 11. 012 ILLUSTRATIVE GAS SUPPLY PIPING (NO OTHER APPLIANCE BELOW COOKTOP) BURNER BOX (REAR OF APPLIANCE) GASKET FLARE UNION ADAPTOR APPLIANCE PRESSURE REGULATOR ALL PIPE JOINTS 1/2" N.P.T. GAS MANIFOLD SHUTOFF VALVES Figure 12. 11 Cooktop & Installation Manual Model COGB ENGLISH 12 ALTERNATIVE PIPING METHODS TO CONNECT APPLIANCE TO GAS SUPPLY A TRAINED SERVICE MAN OR GAS APPLIANCE INSTALLER MUST MAKE THE GAS SUPPLYCONNECTION. Leak testing of the appliance shall be conducted by the Installer according to the Instructions given. Unless prohibited by local codes or ordinances, a new A.G.A. - Certified, flexible metal appliance connector may be used to connect this appliance to its gas supply. The connector must have an internal diameter not less than nominal 1/2” NPT pipe and be no more than 5 feet in length. A 1/2” NPT x 1/2” flare union adapter is required at each end of the flexible connector. If a flexible connector is used assure that both the appliance pressure regulator and manual shut-off valve are joined solidly to other permanent hard piping (either gas supply or the appliance manifold) so as to be physically stationary. See figure 13. CAUTION Do not attempt to attach the flexible connector directly to an external pipe thread. Connection requires flare union adapters. For Massachusetts Installations: 1. Shut-off valve must be a "T" handle gas cock. 2. Flexible gas connector must not be longer than 36 inch. 3. Not approved for installation in a bedroom or a bathroom unless unit is direct vent. MANIFOLD ENTRANCE GASKET GASKET FLARE UNION ADAPTOR FLARE UNION ADAPTOR 1/2" NPT PIPE NIPPLE ELBOW 1/2" NPT PIPE NIPPLE 1/2" NPT PIPE (STATIONARY SUPPLY PIPE) 1/2" NPT PIPE (STATIONARY SUPPLY PIPE) NO APPLIANCE MOUNTED ...

Este manual também é adequado para os modelos :
Hobs - COGB 33060/L/BL (2.84 mb)
Hobs - COGB 33060/L/BL (2.84 mb)
Hobs - COGB33062/SS (2.84 mb)
Hobs - COGB 33061/L/WH (2.84 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias