Instruções de Operação GE, Modelo COGB 33061/L/WH

Fabricante : GE
Arquivo Tamanho: 2.84 mb
Arquivo Nome :
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


Connection requires flare union adapters. For Massachusetts Installations: 1. Shut-off valve must be a "T" handle gas cock. 2. Flexible gas connector must not be longer than 36 inch. 3. Not approved for installation in a bedroom or a bathroom unless unit is direct vent. MANIFOLD ENTRANCE GASKET GASKET FLARE UNION ADAPTOR FLARE UNION ADAPTOR 1/2" NPT PIPE NIPPLE ELBOW 1/2" NPT PIPE NIPPLE 1/2" NPT PIPE (STATIONARY SUPPLY PIPE) 1/2" NPT PIPE (STATIONARY SUPPLY PIPE) NO APPLIANCE MOUNTED BELOW THIS COOKTOP WALL OVEN MOUNTED IN CABINETRY BELOW THIS COOKTOP GAS SHUT-OFF VALVE GAS SHUT-OFF VALVE FLEXIBLE APPLIANCE CONNECTOR 5 FT. MAX (1.52 m) MAX ( ) FLEXIBLE APPLIANCE CONNECTOR 5 FT. MAX (1.52 m) MAX ( ) FLARE UNION ADAPTOR FLARE UNION ADAPTOR FLARE UNION ADAPTOR APPLIANCE PRESSURE REGULATOR, SUPPLIED (OBSERVE DIRECTIONALITY OF GAS FLOW) APPLIANCE PRESSURE REGULATOR, SUPPLIED (OBSERVE DIRECTIONALITY OF GAS FLOW) 013 Figure 13. Cooktop & Installation Manual Model COGB ENGLISH 13 Pressure Testing The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 PSIG (3.5 kPa). This appliance, as well as its individual shut-off valve, must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of 1/2 PSIG (3.5 kPa). When checking appliance regulator function, make certain pressure of natural gas supply is between 6 and 14 inches of water column or, if converted for LP gas, between 11 and 14 inches. THE PRESSURE TESTING SHOULD BE PERFORMED BY MEANS OF THE INJECTOR THREAD ZONE 014 Figure 14. Pressure Test Method • Remove grate and burner cap • Remove aluminum gas spreader • Temporarily remove the injectors • Connect the pressure Test instrument into injector holder thread zone (M6x0,75) • Check if the cooktop has the correct pressure • Fix the injector removed for testing and replace the parts in the right position. Gas test inlet Thread Cooktop & Installation Manual Model COGB ENGLISH Electrical Requirements General Information This appliance must be supplied with the proper voltage and frequency and connected to an individual, properly grounded branch circuit, protected by a circuit breaker or fuse having amperage as noted on the rating plate. We recommend you have the electrical wiring and hookup of your cooktop connected by a qualified electrician. After installation, have the electrician show you where your main cooktop disconnect is located. Check with your local utilities for electrical codes which apply in your area. Failure to wire your cooktop according to governing codes could result in a hazardous condition. If there are no codes, your cooktop must be wired and fused to meet the requirements of the National Electrical Code, ANSI/NFPA No. 70 - Latest edition. You can get a copy by writing: National Fire Protection Association Battery...

Este manual também é adequado para os modelos :
Hobs - COGB 33060/L/BL (2.84 mb)
Hobs - COGB 33060/L/BL (2.84 mb)
Hobs - COGB33062/SS (2.84 mb)
Hobs - COGB 33061/L/WH (2.84 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias