Log:
Assessments - 3, GPA: 4.7 ( )

Instruções de Operação GE, Modelo CLIMATISEUR AEH25*

Fabricante : GE
Arquivo Tamanho: 2.32 mb
Arquivo Nome :
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


Since fan only settings do not provide cooling, a Set temperature cannot be entered. The room temperature will appear in the display. NOTE: Auto Fan Speed cannot be used when in the Fan Only Mode. Auto Fan Speed Set to Auto fan speed for the fan speed to automatically set to the speed needed to provide optimum comfort settings with the set temperature. If the room needs more cooling, the fan speed will automatically increase. If the room needs less cooling, the fan speed will automatically decrease. NOTE: Auto Fan Speed cannot be used when in the Fan Only Mode. Power Outage Recovery Feature In the case of a power outage or interruption, the feature was set, it will resume countdown. You may unit will automatically re-start in the settings last need to set a new time if desired. used after the power is restored. If the Delay 1–24hr Remote Control ¦ To ensure proper operation, aim the remote ¦ Make sure nothing is between the air conditioner control at the signal receiver on the air and the remote control that could block the conditioner. signal. ¦ The remote control signal has a range of ¦ Make sure batteries are fresh and installed up to 20 feet. correctly as indicated on the remote control. 5 About the controls on the air conditioner—models with control knobs. Consumer Support Troubleshooting TipsInstallationInstructionsCare and CleaningOperatingInstructionsSafety Instructions Features and appearance will vary. The air conditioner controls are located behind the control panel door. Press to open and close the door. Mode Control High Cool, Med Cool and Low Cool provide cooling with different fan speeds. Fan settings provide air circulation and filtering without cooling. NOTE: If you move the mode control from a cool setting to OFF or to a fan setting, wait at least 3 minutes before switching back to a cool setting. Cooling Descriptions For Normal Cooling—Select High Cool or Med Cool with the TEMPERATURE control at midpoint. For Maximum Cooling—Select High Cool with the TEMPERATURE control at the highest number available on your knob. For Quieter & Nighttime Cooling—Select Low Cool with the TEMPERATURE control at midpoint. TEMPERATURE CONTROL (on some models) MODE Low Cool HighCool OFF HighFan Low Fan Med Cool 7Coolest 6 5 4 3 2 1 TEMP MODE CONTROL (on some models) Controls TEMP Control The TEMP control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number, the indoor air will become cooler. Turn the knob to a lower number and the indoor air will become warmer. CIRCULAIRE For continuous side-to-side air circulation, set the Circulaire switch to ON. For fixed side-to-side air direction, set the Circulaire switch to ON until the desired air direction is obtained, then move it to OFF. TEMPERATURE MODE CONTROL CONTROL (on some models) (on some models) Temp Control The temp control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. Turn the knob clockwise to Cooler (blue) and indoor air will become cooler. Turn knob counterclockwise to Warmer (red) and the indoor air will become warmer. Mode Control Hi Cool and Low Cool provide cooling with different fan speeds. Hi Heat and Low Heat provide heating with different fan speeds. Fan Only setting provides air circulation and filtering without cooling or heating. NOTE: If you move the mode control from a cool setting to Off, a fan setting or a heat setting, wait at least 3 minutes before switching back to a cool setting. Cooling Descriptions For Normal Cooling—Select Hi Cool or Low Cool with the temp control at midpoint. For Maximum Cooling—Select Hi Cool with the temp control turned clockwise as far as possible. For Quieter & Nighttime Cooling—Select Low Cool with the temp control at midpoint. Heating Descriptions For Normal Heating—Select Hi Heat or Low Heat with the temp control at midpoint. For Maximum Heating—Select Hi Heat with the temp control turned counterclockwise as far as possible. For Quieter & Nighttime Heating—Select Low Heat with the temp control at midpoint. Circulaire For continuous side-to-side air circulation, set the Circulaire switch to On. For fixed side-to-side air direction, set the Circulaire switch to On until the desired air direction is obtained, then move it to Off. Additional controls. ge.com Vent Control The vent control is located above the control panels. When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some outside air is let into the room. To open the vent, push the lever to the right. To close it, push it to the left. Consumer SupportTroubleshooting and Instructions Air Direction—Up and Down Fingertip pressure on the horizontal louvers adjusts the air direction up or down. Control Panel Door Press to open and close the door. NOTE: The remote control (on some models) will work wi...

Este manual também é adequado para os modelos :
Hobs - CLIMATISEUR AEH18* (2.32 mb)
Hobs - CLIMATISEUR AEE23 (2.32 mb)
Hobs - CLIMATISEUR AEM18* (2.32 mb)
Hobs - CLIMATISEUR AEM25* (2.32 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias