Instruções de Operação Stovax, Modelo SLBV-35PM

Fabricante : Stovax
Arquivo Tamanho: 2.89 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


4. Removethecoverplate'sknockout;then feed the power supply wire through the knockout opening and into the unit junction box. 5. Connect the black power supply wire to the lower outlet's red pigtail lead and the white power supply wire to the common terminal of the outlet as shown in Figures 13 and 14. 6. Connect ground supply wire to pigtail lead attached to outlet's green ground screw. Note: Remote receiver should be located in the wall, or if installed in the control compartment, pulled all the way forward and completely to the left or right against the corner posts. The glass enclosure panel must be removed first to place the receiver in the lower control compartment. 7. If using an optional control, wire it in the low voltage circuit as shown in Figure 13. Note:Thesupplied15feetof2conductorwire has one end of each conductor connected to the gas valve circuit and the other end of each conductor placed loose inside the bottom compartment. 8. After wiring is complete, replace cover plate. Note: Do NOT install batteries in the battery holder until needed (i.e., in the event of a power outage or if operating the appliance solely by batteries). The battery holder requires two [2] "D" batteries. NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. SUPERIORSUPERIORB-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Figure 12 MILLIVOLT WIRING dIAGRAM CAUTION: WHEN SERVICING CONTROLS, LABEL ALL WIRES PRIOR TO dISCONNECTION. WIRING ERRORS CAN CAUSE IMPROPER ANd dANGEROUS OPERATION. VERIfY PROPER OPERATION AfTER SERVICING. If any of the original wire must be replaced, use Type AWM 105. C - 18 gage wire ONLY. High Limit Switch Control Switch* Gas Control Valve Terminals Thermopile THTPHTPTB-VENT APPLIANCES ONLY: The High Limit Switch must be factory installed in series, as shown. If wires to this switch must be replaced, use Type AWM 200°C - 18 gage wire ONLY. _________ *Control switch options: ON/OFF wall switch, unit-mountable ON/OFF switch, or ON/OFF remote control system (see "Accessory Components" in the Care and Operation Instructions). ELECTRONIC IGNITION WIRING dIAGRAM _________ *Control switch options: ON/OFF wall switch, unit-mountable ON/OFF switch, or ON/OFF remote control system (see "Accessory Components" in the Care and Operation Instructions). TRANSFORMER 3V BROWN BROWN BLACK BATTERY BACK-UP BLACK (SENSOR) BLACK (IGNITER) IGNITER MODULE 3V RED PILOT INOUT VENT LO HI THTP TH TP IN ORANGE (THTP) BLACK (TP) GREEN (TH) HIGH LIMIT SWITCH Pilot Burner Pilot Tube Assembly Schematic Representation Only Electronic Gas Control Valve - DEXEN B-Vent appliances only -High limit switch must be factory installed as shown. If wires to this switch are replaced, wires must be Type AWM 200°C -18 gage wire ONLY. CONTROL SWITCH * UNIT MOUNTED ON/OFF SWITCH, IF SUPPLIED Junction Box J-Box Wiring BK W G CAV021* Control Switches: Wall On/Off or Remote Control Switch. Switch, Unit Mounted On/Off...

Este manual também é adequado para os modelos :
Lareiras - SLBV-35NE (2.89 mb)
Lareiras - SLBV-35NE (2.89 mb)
Lareiras - SLBV-35NE (2.89 mb)
Lareiras - SLBV-35NE (2.89 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias