Log:
Assessments - 2, GPA: 4 ( )

Instruções de Operação Monessen Hearth, Modelo SLBV-35NM

Fabricante : Monessen Hearth
Arquivo Tamanho: 2.89 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Refer to Figure 18. Insert the last length of gas pipe with its attached shut-off valve into the lower control compartment, and pass it through the gas line access hole on the left side of the appliance outer wrapper. Using appropriate materials for the gas type, thread the last length of pipe into the end of the gas vent run and tighten in place using a Length of pipe with attached Gas Shut-Off Valve in OFF position (gas line CLOSED) Figure 18 Figure 16: Gas Connection Gas Valve 3/8" NPT x Flare Fitting 3/8" Flex Tubing 3/8" Nipple 3/8" Union 3/8" Close Nipple 3/8" Shut-off Valve 1/2" x 3/8" Reducer Gas Stub 1/2" x 3/8" Flare Shut-off Valve Gas Solid Line Connector Gas Flex Line Connector *Sediment Trap 3" Min Note: The gas supply line must be installed in accordance with building codes by a qualified installer approved and/or licensed as required by the locality. In the Commonwealth of Massachusetts, installation must be performed by a licensed plumber or gas fitter. Gas Flex Line (Gas Shut-Off Valve is behind door latch; see DETAIL, below) Gas Control Valve Piezo (Millivolt units only) Spring Door Latch (one of two) Lower Control Compartment (shaded area) Optional Unit-Mounted ON/OFF Switch ~ { Note: Millivolt system shown. Electronic system controls are similarly located. DETAIL: Gas Shut-Off Valve in ON position (gas line OPEN) To shut OFF gas: Turn valve handle perpendicular (cross-wise) to gas line. pipe wrench external to the appliance between the appliance outer wrapper and the framing. Important: Turn the last piece of gas pipe in the last fitting until the shut-off valve is positioned in a way that allows the shut-off valve handle to be accessed in the lower control compartment, easily operated throughout its full range of motion. Bring the flex-line to the shutoff valve by hand and align the flare fittings. Tighten the fittings by hand, and then use wrench to tighten completely, 1/4-turn at a time. 15 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. DETAIL: Lower Control Compartment Door Tab SUPERIOR SUPERIORB-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS Test All Connections for Gas Leaks (factory and field) WARNING Never use an open flame to check for leaks. Turn on gas supply and test for gas leaks, using a gas leak test solution (also referred to as bubble leak solution). Note: Using a soapy water solution is an effective leak test solution but it is not recommended, because the soap residue that is left on the pipes/fittings can result in corrosion over time. A. Light the appliance (refer to the lighting instructionslabelinthecontrolcompartment or in the Care and Operation Instructions manual). B. Brush all joints and connections with the gas leak test solution to check for leaks. If bubbles are formed, or gas odor is detected, turn the gas control knob (off/pilot/on) to the “OFF” position. Either tighten or refasten the leaking connection, then retest as described above. C. When the gas lines are test...

Este manual também é adequado para os modelos :
Lareiras - SLBV-35NE (2.89 mb)
Lareiras - SLBV-35NE (2.89 mb)
Lareiras - SLBV-35NE (2.89 mb)
Lareiras - SLBV-35NE (2.89 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias