|
Facilidade de uso
Refer to Figure 16 for floor and platform installations. If the heater is to be installed into a framed wall refer to the built-in assembly steps beginning on page 4. Note:The heater may be installed directly on a floor made of standard combustible wood construction materials. Do not install the heater directly on carpeting or other soft floor covering such as vinyl tile or flooring materials. Use a wood or metal panel that extends the full width and depth of the heater between the heater and any soft floor covering material. Refer to Figures 26 and 27 for base dimensions. Step 9. Secure Heater – Bend the tabs down (Figures 2 and 15). Using two (2) screws securely tighten the appliance to the platform. Note:Heater must be anchored to the floor or platform. Step 10. Install Optional 120V Wiring – Refer to Step 5 for wiring instructions. Connecting Gas Line Step 11. A qualified gas appliance installer must connect the gas room heater to the gas supply. Consult all local codes and refer to Step 5. The heater gas inlet connection is 3/8" NPT, located on the left side facing the heater. If a right side connection is required, the connection pipe may be piped under the rear of the appliance to end at the left hand side for connection to the inlet. When tightening up the joint to the valve hold the valve securely with a wrench to prevent the valve from moving. Step 12. For Surround Installations Only – Finish the assembly of the surround components and secure the surround to the appliance. Assembling the Logs WARNING: DO NOT ADD EXTRA LOGS OR ORNAMENTS SUCH AS PINE CONES, VERMICULITE OR ROCK WOOL. USING THESE ADDED ITEMS CAN CAUSE SOOTING. WARNING: DO NOT PLACE ANY LAVA ROCK ON LOGS OR BURNERS. THIS MAY CAUSE SOOTING. Step 13. The heater includes a unitized set of ceramic fiber logs. Handle these logs with great care. The logs can be easily damaged, but when handled properly they can provide years of performance and enjoyment. Position the unitized log set unto the burner as shown in Figure 17. Figure 17 After setting the logs into position as shown above, ensure they are properly and firmly situated. The heater will not function as in- tended if the logs are not correctly positioned. Periodically check the positioning of the logs. WARNING: FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS HEATER MAY RESULT IN PROP- ERTY DAMAGE OR PERSONAL INJURY. Flame Appearance REFER TO THE OPERATING INSTRUCTIONS LOCATED AT THE BACK OF THIS MANUAL BEFORE LIGHTING THE HEATER TO OBSERVE THE FLAMES. Flames from the pilot, front and rear burner should be visually checked as soon as the heater is installed. In addition a periodic visual check of the flames should be made. The pilot flame should always be present when the heater is in operation and should just envelope the tip of the thermocouple (Figure 18). WARNING: NO ADJUSTMENTS ARE TO BE MADE TO THE ODS PILOT SYSTEM. TAMPERING WITH THIS SYSTEM CAN BE EXTREMELY HAZARDOUS. Figure 18 An ...
Este manual também é adequado para os modelos :Lareiras - VF5000-CMP-2 (1006.8 kb)
Lareiras - VF5000-CMN-2 (1006.8 kb)
Lareiras - VF5000-CMN-2 (1006.8 kb)
Lareiras - VF5000-CMN-2 (1006.8 kb)