Log:
Assessments - 4, GPA: 4.3 ( )

Instruções de Operação Superior, Modelo VF6000-CMP-2

Fabricante : Superior
Arquivo Tamanho: 1006.8 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


• The heater must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. • Any safety screen or guard removed for servicing the heater must be replaced prior to operating the heater. • Keep heater area clear and free from combustible materials, gasoline and other flammable vapors and liquids. • Do not use these appliances if any part has been under water. Immediately call a qualified professional service technician to inspect the appliance and to replace any parts of the control system and any gas control which have been under water. • Test gage connections are provided on the front of the gas control valve (identified A for the manifold side and E for inlet pressure). • Input ratings are shown in BTU per hour and are for elevations up to 7,000 feet. Operating heater above elevations of 7,000 feet may cause ODS pilot outage. • Ensure that the heater is clean when operating. Excessive dust accumulation on the burner and logs will increase the amount of carbon monoxide formation and could lead to carbon monoxide poisoning and death. CODES Adhere to all local codes or in their absence the latest edition of The National Fuel Gas Code ANSI Z223.1 or NFPA54 which can be obtained from The American National Standards Institute, Inc. (1430 Broadway, New York, NY, 10018) or National Fire Protection Association, Inc. (Batterymarch Park, Quincy, MA, 02269). Massachusetts And New York Requirements These appliances are approved for installation in the following USA locations listed in the following: Massachusetts: These fireplaces are approved for installation in the US state of Massachusetts if the following additional requirements are met • Installation and repair must be done by a plumber or gas fitter licensed in the Commonwealth of Massachusetts. • The flexible gas line connector used shall not exceed 36 inches (92 centimeters) in length. • The individual manual shut-off must be a T- handle type valve. • Vent-Free appliances may NOT be installed in bedrooms or bathrooms. • A working smoke detector must be installed in the area where vent-free appliances are installed. Seller of unvented propane or natural gas- fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit. New York: These appliances are approved for installation in the US state of New York, but not in New York City. COMBUSTION AND VENTILATION AIR These heaters shall not be installed in a confined space. The heater may be located in unusually tight construction provided the space is unconfined, or if confined, is provided with two permanent openings communicating directly with an additional room(s) of sufficient volume so that the combined volume of all connected spaces meets the criteria for an unconfined space, (National Fuel Gas Code ANSI Z223.1 (latest edition), Section 5.3). Generally 50 ft 3 per 1,000 BTU input of all operating applia...

Este manual também é adequado para os modelos :
Lareiras - VF5000-CMP-2 (1006.8 kb)
Lareiras - VF5000-CMN-2 (1006.8 kb)
Lareiras - VF5000-CMN-2 (1006.8 kb)
Lareiras - VF5000-CMN-2 (1006.8 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias