Fabricante : Superior
Arquivo Tamanho: 2.89 mb
Arquivo Nome :
|
Facilidade de uso
Le tecnicien agreeestresponsabledel’installationdecettetrousse.L’installationn’est pas adequate ni complete tant que le bon fonctionnement de l’appareil convertin’apaseteverifieselonlesinstructionsdufabricantfourniesavec la trousse. Le fournisseur de service qualifie ayant realise l'installation assume les responsabilites liees a la conversion. GAS CONVERSION KITS In Canada: THE CONVERSION SHALL BE CARRIEd OUT IN ACCORdANCE WITH THE REqUIREMENTS Of THE PROVINCIAL AUTHORITIES HAVING JURISdICTION ANd IN ACCORdANCE WITH THE REqUIREMENTS Of THE CAN/ CSA-B149.1 INSTALLATION COdE. LA CONVERSION dEVRA eTRE EffECTUeE CONfORMeMENT AUX RECOMMANdATIONS dES AUTORITeS PROVINCIALES AYANT JURIdICTION ET CONfORMeMENT AUX EXIGENCES dU COdE d'INSTALLATION CAN/CSA-B149.1. Gas conversion kits are available to adapt your appliance from the use of one type of gas to the use of another. These kits contain all the necessary componentsneededtocomplete the task including labeling that must be affixed to ensure safe operation. Kit part numbers are listed here and the followingstepsdetailtheconversionprocedure. Refer totheinstructionsprovidedwiththeconversion kit when performing any gas conversion. Millivolt SIT Systems Natural Gas To Propane Gas Conversion Kits Models Catalog No. SLBV-35 H8270 SLBV-40 H7673 Millivolt SIT Systems Propane Gas to Natural Gas Conversion Kits Models Catalog No. SLBV-35 H8271 SLBV-40 H7675 Electronic dEXEN Systems Natural Gas To Propane Gas Conversion Kits Models Catalog No. SLBV-35 H8268 SLBV-40 H7669 Electronic dEXEN Systems Propane Gas To Natural Gas Conversion Kits Models Catalog No. SLBV-35 H8269 SLBV-40 H7671 Gas Conversion Kit Installation Instructions Step 1. TURN Off THE GAS SUPPLY TO THE APPLIANCE and disconnect power supply at the circuit breaker. Ensure appliance is cold. CAUTION: THE GAS SUPPLY SHALL BE SHUT Off PRIOR TO dISCONNECTING THE ELECTRICAL POWER, BEfORE PROCEEd- ING WITH THE CONVERSION. ATTENTION: AVANT d’EffECTUER LA CONVERSION, COUPEz d’ABORd L’ALIMENTATION EN GAz, ENSUITE, COUPEz L’ALIMENTATION eLECTRIqUE. Step 2. Remove the front glass enclosure panel. See Figure 25 on Page 20. Step 3. Carefully remove the logs. Note: Logs are fragile. Handle gently to prevent breakage. Step 4. Refer to Figure 31. Remove the burner assembly with attached venturi tube. for Millivolt Systems, continue to Step 5. for Electronic Systems, skip to Step 8. Step 5. SIT Millivolt Valve: Refer to Figure 32 and the instructions provided with the kit. a. Using a Torx T20 (with 1/4" shank and center hole), remove and discard the three pressure regulator mounting screws. b. Remove the pressure regulator, spring, poppet, diaphragm and bushing. c. discard all removed components. d. Make sure the rubber gasket installed on the back of the replacement pressure regulator is properly positioned. Tighten screws to 25 in.-lb. torque. NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Electronic Appliances Step 8. Dexen Electronic Valves: Refer to Figure 34 an...
Este manual também é adequado para os modelos :Lareiras - SLBV-35NE (2.89 mb)
Lareiras - SLBV-35NE (2.89 mb)
Lareiras - SLBV-35NE (2.89 mb)
Lareiras - SLBV-35NE (2.89 mb)