During the first year after the date of purchase, BRK Brands, Inc. will replace any defective carbon monoxide alarm without charge. During the next four years, BRK Brands, Inc. will replace any defective carbon monoxide alarm at a charge to you not to exceed BRK Brands, Inc.’s cost. This is your exclusive warranty. This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable. Keep the original sales receipt. Proof of purchase is requir
2. Immerse the reagent pads into water sample for 2 seconds, remove, after 1 minute match colors to chart below. Total Nitrate/Nitrite (as N) (end pad) 3. Colors are stable for 1 minute. 0 0.5 2.0 5.0 Nitrite (as N) (pad nearest handle) 10 20 50 ppm 0 0.15 0.3 1.0 1.5 3.0 10 ppm pH / hardness / chlorine test instructions 1. Carefully open pH / Hardness / Chlorine Test packet and take out test strip. 2. Immerse the reagent pads into water sample immediately. Hold the strip level for 15 seconds. 3
KFE2S5 M06-3008-00X M 04/02 Model KFE2S5 IMPORTANT! Please read carefully and save. This user’s manual contains important information about your fire extinguisher’s operation. If you are installing this fire extinguisher for use by others, you must leave this manual—or a copy of it—with the end user. Read extinguisher label and the entire user’s manual carefully before installing or using the unit. Make sure everyone in your household is completely familiar with the operation of the extinguisher
2002RAC BEDROOMBEDROOM HALL LIVING ROOM KITCHEN FINISHED BASEMENT REQUIRED TO MEET NFPA RECOMMENDATIONS RECOMMENDED FOR ADDITIONAL PROTECTION BEDROOM BEDROOM KITCHEN LIVING ROOM DINING ROOM MULTI-STORY RESIDENCE SINGLE-STORY RESIDENCE, APARTMENT, MOBILE HOME KEY: EXISTING HOMESSMOKE ALARMS WITH SILENCE FEATURES RECOMMENDED FOR ADDITIONAL PROTECTION INTERCONNECTED AC OR AC/DC SMOKE ALARMS BEDROOMBEDROOM HALL LIVING ROOM KITCHEN FINISHED BASEMENT REQUIRED TO MEET NFPA RECOMMENDATIONS RECOMMENDED F
SC1000B One Alarm That Provides Protection Against Two Deadly Threats! SMOKE& CARBON MONOXIDE ALARM 9V BATTERY POWERED Cat. No. SC1000B One Alarm That Provides Protection Against Two Deadly Threats! SMOKE& CARBON MONOXIDE ALARM 9V BATTERY POWERED Features Benefits Battery Powered Works even during a power outage. Combined Carbon Monoxide Alarm and Smoke Alarm in one unit Alerts you of elevated carbon monoxide levels and provides an early warning of smoke from fire. Minimizes the number of CO Ala
The installation of smoke alarms in kitchens, attics ( finished or unfinished), or garages is not normally recommended, as these locations occasionally experience conditions that can result in improper operation. California State Fire Marshall Early warning detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows: A smoke alarm installed in each separate sleeping area (in the vicinity, but outside bedrooms), and heat or smoke a
• Where it is easy to reach, near an exit or an escape route from the room. • In a location that is convenient, in plain sight, and 3-1/2 to 5 feet above the floor. • Store the extinguisher high enough to keep it out of the reach of small children. • On a clean, dry surface where the temperature does not go above 120° F (49° C) or below –40° F (-40°C). HOW TO INSTALL THIS EXTINGUISHER • Do not mount the extinguisher on drywall or plaster without adequate support. Use strong screws or bolts to mo
HOW TO OPERATE YOUR FIRE EXTINGUISHER IN A FIRE EMERGENCY • Make sure your extinguisher may be safely and effectively used on the small fire you want to fight. Always use extreme caution when fighting any fire. Fight a fire only where there is a clear escape path to allow you to get out safely if the fire gets worse. • Avoid breathing smoke and heated fumes; stay low if necessary. Burning materials will release toxic fumes. Inhaling these fumes may cause injury or death. • Always stand back far
It is pressurized and could rupture or explode if exposed to temperatures over 150°F (66°C). • This extinguisher contains a dry powder extinguishing agent. The agent/powder is not toxic, but can irritate skin. When using this unit, avoid breathing the powder. Always ventilate the area after use. WHERE TO INSTALL THIS EXTINGUISHER A Fire Extinguisher Should Be Mounted: • In the vicinity of (but not on or in) a potential source of heat and/or fire, like an oven or stove. • Where it is easy to reac
5. Review the manual and instruction label with everyone in your home. Everyone should know how to use the extinguisher in an emergency. 6. When you finish inspecting the extinguisher, put it back securely into the mounting bracket. IMPORTANT! For more information about fire extinguishers, consult the NFPA Standard #10, "Portable Fire Extinguishers," available from the National Fire Protection Association, Inc., Batterymarch Park, Quincy, MA 02169, USA. HOW TO OPERATE YOUR FIRE EXTINGUISHER IN A