|
Facilidade de uso
SUPERIOR® DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS Gas Controls/Control Compartment Access The gas controls can be found behind the control compartment access door. Removing Control Compartment Door: Open the panel by gently lifting it upward and forwards. Slide the door, first to one side and then the other, so the tabs clear both of the locating holes. Operation and care of your appliance WARNING Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces. AVERTISSEMENT Les jeunes enfants devraient etre surveilles etroitement lorsqu’ils se trouvent dans la meme piece que l’appareil. Les tout petits, les jeunes enfants ou les adultes peuvent subir des brulures s’ils viennent en contact avec la surface chaude. Il est recommande d’installer une barriere physique si des personnes a risques habitent la maison. Pour empecher l’acces a un foyer ou a un poele, installez une barriere de securite; cette mesure empechera les tout petits, les jeunes enfants et toute autre personne a risque d’avoir acces a la piece et aux surfaces chaudes. Figure 1 On millivolt systems, the piezo igniter, HI/LO flame adjustment knob, and pilot and main gas OFF/ON control knob are located below the glass panel enclosure. The gas valve for electronic systems is also located below the glass enclosure panel (see Figure 1). Reinstalling Control Compartment Door: To reinstall, insert the tabs on each side of the door into the corresponding holes in the control compartment opening, one side first then the other. To close, pull the door gently up and close by pushing forward and pushing the top edge down into the groves at the brackets until it locks in place. The standard controls for appliance operation are located behind the panel below the appliance front glass enclosure panel (Figure 1). Optional control switches are also available (see Page 19 - Remote Wall Switch, Remote Control, Unit Mounted Rocker Switch or Wall Thermostat). Operation of millivolt and electronic gas control systems are different. Before lighting and operating your appliance determine if you have a millivolt or electronic appliance. Familiarize yourself with the gas control valve that your appliance uses. Refer to Figure 1 for access to the gas control valve. Millivolt Appliances - Appliances with Millivolt systems will be fitted with the gas control valve shown in Figure 3. Electronic Appliances - Appliances with electronic systems will be fitted with the electronic valve shown in Figure 4. Millivolt Appliances - To light millivolt appliances refer to Figure 1. Detailed lighting inst...
Este manual também é adequado para os modelos :Lareiras - SLDVT-30NE (2.16 mb)
Lareiras - SLDVT-30NE (2.16 mb)
Lareiras - SLDVT-30NE (2.16 mb)
Lareiras - SLDVT-30NE (2.16 mb)