Log:
Assessments - 2, GPA: 4 ( )

Instruções de Operação Superior, Modelo SLDVT-35NM

Fabricante : Superior
Arquivo Tamanho: 2.16 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Input (BTU/HR) Manually-Modulated Gas Valves (all models) Models Input Rate (BTU / HR) Nat. Gas Prop. Gas SLDVT-30 13,500 high 10,000 low 11,500 high 9,000 low SLDVT-35 16,000 high 12,750 low 15,000 high 11,400 low SLDVT-40 20,000 high 15,500 low 18,000 high 14,000 low SLDVT-45 23,000 high 17,500 low 22,000 high 17,000 low Table 1 Gas Pressure Requirements (All Models) Gas pressure requirements are listed in Tables 2 and 3. Test gauge connections are provided on the front of the millivolt gas control valve, identified IN for the inlet and OUT for the manifold side (see Figure 3 on Page 9). A 1/8" NPT Test gauge connection is provided at the inlet and outlet (manifold) ports on the electronic gas control valve (see Figure 4 on Page 9). 8 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. SUPERIOR® DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS Gas Controls/Control Compartment Access The gas controls can be found behind the control compartment access door. Removing Control Compartment Door: Open the panel by gently lifting it upward and forwards. Slide the door, first to one side and then the other, so the tabs clear both of the locating holes. Operation and care of your appliance WARNING Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces. AVERTISSEMENT Les jeunes enfants devraient etre surveilles etroitement lorsqu’ils se trouvent dans la meme piece que l’appareil. Les tout petits, les jeunes enfants ou les adultes peuvent subir des brulures s’ils viennent en contact avec la surface chaude. Il est recommande d’installer une barriere physique si des personnes a risques habitent la maison. Pour empecher l’acces a un foyer ou a un poele, installez une barriere de securite; cette mesure empechera les tout petits, les jeunes enfants et toute autre personne a risque d’avoir acces a la piece et aux surfaces chaudes. Figure 1 On millivolt systems, the piezo igniter, HI/LO flame adjustment knob, and pilot and main gas OFF/ON control knob are located below the glass panel enclosure. The gas valve for electronic systems is also located below the glass enclosure panel (see Figure 1). Reinstalling Control Compartment Door: To reinstall, insert the tabs on each side of the door into the corresponding holes in the control compartment opening, one side first then the other. To close, pull the door gently up and close by pushing forward and pushing the top edge down into the groves at the brackets until it locks in place. The standard controls for appliance operation are located behind the panel below the appliance front glass enclosure pan...

Este manual também é adequado para os modelos :
Lareiras - SLDVT-30NE (2.16 mb)
Lareiras - SLDVT-30NE (2.16 mb)
Lareiras - SLDVT-30NE (2.16 mb)
Lareiras - SLDVT-30NE (2.16 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias