Facilidade de uso
Check for spark at electrode and pilot; if no spark and electrode wire is properly connected, replace igniter. WARNING: if the pilot will not light after 1 minute of attempting, wait for at least 5 minutes for gas to clear before attempting again. B. Defective or misaligned electrode at pilot (spark at electrode). Using a match, light pilot. If pilot lights, turn off pilot and trigger the igniter button again. If pilot lights, an improper gas mixture caused the bad lighting and a longer purge period is recommended. If pilot will not light – check gap at electrode and pilot – should be 1/8" to have a strong spark. If gap measures 1/8", replace pilot (see Figure 16 on Page 17). C. Gas supply pressure errant. Check inlet gas pressure. It should be within the limits as marked on the rating plate. D. Pilot orifice plugged. Clean or replace pilot orifice. 2. Pilot will not stay lit after carefully following the lighting instructions. A. Defective pilot generator (thermocouple). Check pilot flame, it must impinge on thermocouple (see Figure 16 on Page 17). Clean and/or adjust pilot for maximum flame impingement on thermocouple. Ensure that the connection between the valve and thermocouple are tight and secure. 3. Pilot burning, no gas to burner, Valve knob “ON,” and the (standard) burner OFF/ON switch is “ON." Read important note below. A. Wall switch or wires defective. Check wall switch and wires for proper connections. Jumper wire across terminals at wall switch, if burner comeson,replacedefectivewallswitch.Ifokay,jumper wires across wallswitchwiresatvalve,if burner comes on, wires are faulty or connections are bad. IMPORTANT NOTE: If an optional *remote switch is used for burner operation, if the standard burner OFF/ON switch is still installed on appliance it must be in the "OFF" position. B. Thermopile may not be generating sufficient millivolts. Check thermopile with millivolt meter. Take reading at thermopile terminals of gas valve. Should read 325 millivolts minimum with optional wall switch “OFF.” Replace faulty thermopile if reading is below specified minimum. C. Plugged burner orifice. Check burner orifice for blockage and remove. *Optional remote switch kits - wall switch, wall thermostat or remote control. D. OFF/ON Switch and *Remote Switch are in the "ON" position resulting in excessive resistance. When turning on the burner using a *remote switch, ensure that the standard OFF/ON switch is in the "OFF" position. If both switches are in the ON position, it may result in excessive resistance (and millivolt drainage) and the burner may not come on. 4. Frequent pilot/burner outage problem. A. Pilot flame may be too low or blowing (high) causing the pilot/valve safety to drop out. Clean and/or adjust pilot flame for maximum flame impingement on thermocouple (see Figure 16 on Page 17). SUPERIORSUPERIORDIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM Note: Bef...
Este manual também é adequado para os modelos :Lareiras - SLDVT-30NE (2.16 mb)
Lareiras - SLDVT-30NE (2.16 mb)
Lareiras - SLDVT-30NE (2.16 mb)
Lareiras - SLDVT-30NE (2.16 mb)