Wayne 351301-001

Downloads : 0 Arquivo Tamanho: 121 kb    Fabricante : Wayne  
Categoria : Canalização

Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. Submersible Utility Pump Description This portable, submersible utility pump is designed for non-automatic use in water. The units are equipped with an 8 ft. 3-prong grounding type power cord. The motor is oil filled and sealed for cooler operation. The discharge fitting is designed for convenient at

Wayne TSC

Downloads : 1 Arquivo Tamanho: 121 kb    Fabricante : Wayne  
Categoria : Canalização

If the power source is out of sight, lock and TAG IN OPEN (OFF) POSITION to prevent unexpected power application. Failure to do so could result in fatal electrical shock! This unit is not designed for use in septic tanks or underground vaults to pump raw sewage or effluents. Never use in hazardous or explosive locations. 1. This pump has been designed to attach to a standard garden hose. Thread the female end of the garden hose to the male discharge on the pump. 2. To reduce leakage between the

Wayne P265F

Downloads : 4 Arquivo Tamanho: 244 kb    Fabricante : Wayne  
Categoria : Greeley

Gas Pg. 15 1 Orifice Holder Assy. 5” (127mm) Burner 60155 • • • • 1 Orifice Holder Assy. 8” (203.2mm) Burner 60249 • • • • 1 Orifice Holder Assy. 11” (279.4mm) Burner 60250 • • • • 1 Elbow - 1/2” (12.7mm) Pipe - Black Iron 60001 • • • • 1 Valve Spring Kit 62672-004 • • 1 Nipple - 1/2” (12.7mm) Pipe - Special 60013 • • 1 Piezo Ignitor 63213-001 • • 1 Ignitor Wire 5” (127mm) Burner 63217-001 • • 1 Ignitor Wire 8” (203.2mm) Burner 63217-002 • • 1 Ignitor Wire 11” (279.4mm) Burner 63217-003 • • 1 Ga

Wayne P265

Downloads : 3 Arquivo Tamanho: 244 kb    Fabricante : Wayne  
Categoria : Greeley

The pressure should be neutral at the center. Closing the adjuster lowers the neutral pressure point and opening the adjuster raises the neutral pressure point. Once the neutral pressure point has been adjusted, the combination air shutter should be adjusted so that the percent CO2 test must be made at the inlet side of the draft hood. If the CO2 reading is not within the recommended limits, then the combustion air shutter should be re-adjusted and then the neutral pressure point be rechecked an

Wayne P265-EP

Downloads : 2 Arquivo Tamanho: 244 kb    Fabricante : Wayne  
Categoria : Greeley

POWER INTERRUPTION System shuts off, restarts when power is restored. PILOT FLAME FAILURE Mail valve closes. Module starts trial for ignition. WIRING DIAGRAM LADDER FORM WIRING DIAGRAM HONEYWELL EP SYSTEM S86 14 S8600, S8610 TROUBLESHOOTING GUIDE START NOTE: Before troubleshooting, familiarize yourself with the start up and checkout procedure. TURN GAS SUPPLY OFF, TURN THERMOSTAT (CONTROLLER) TO CALL Check line voltage power, low voltage transformer, limit controller, thermostat (controller) and

Wayne P250AF-DI

Downloads : 0 Arquivo Tamanho: 244 kb    Fabricante : Wayne  
Categoria : Greeley

in. (645.2 mm2) for each directly to outdoor air. 1,000 Btu (.2931 kW) (.2931 kW) per hourper hour input. Attic Ventilation Louvers are required at each end of attic with alternate air inlet No. 1. 1, 2, and 3 mark alternate locations for air from outdoors. Free area shall be not less than 1 Sq. in. (645.2 mm2) per 5,000 Btu (.1.465 kW) per hour of the total per hour of the total input rating of all appliances in the enclosure. Crawl-space Ventilation Louvers for unheated crawl space are require

Wayne P250AF

Downloads : 8 Arquivo Tamanho: 244 kb    Fabricante : Wayne  
Categoria : Greeley

English values take priority. FOR YOUR SAFETY IF YOU SMELL GAS: 1. OPEN WINDOWS 2. DON’T TOUCH ELECTRICAL SWITCHES 3. EXTINGUISH ANY OPEN FLAME 4. IMMEDIATELY CALL YOUR GAS SUPPLIER. WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. -Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. -WHAT TO DO IF YOU SMELL GAS • Do not try to

Wayne P250AF-EP

Downloads : 0 Arquivo Tamanho: 244 kb    Fabricante : Wayne  
Categoria : Greeley

(1121Pa) for natural gas and 11.0” w.c. (2740Pa) for L.P. gas; the maximum gas supply pressure is 10.5: w.c. (2615Pa) for natural gas and 13” w.c. (3238Pa) for L.P. gas. P250 ONLY Input BTU/Hr. (kW/Hr.) Floor Area Sq. Inches (mm2) Preferred Width and Length (mm) Recommended Minimum Wall Thickness Recommended Minimum Floor Construction 50,000 (14.65) 49 (31610) 7(177.8)x7 (177.8) 2 1/2” (63.5mm) insulating firebrick plus back up of 1 1/2” (38.1mm) or more loose insulation. 2 1/2” (63.5mm) Insulat

Wayne 331400-001

Downloads : 2 Arquivo Tamanho: 256 kb    Fabricante : Wayne  
Categoria : Canalização

The pump motor is equipped with automatic resetting thermal protector and may restart unexpectedly. Protector tripping is an indication of motor overloading as a result of operating the pump at low heads (low discharge restriction), excessively high or low voltage, inadequate wiring, incorrect motor conditions, or a defective motor or pump. 14. This pump is designed to transfer water in cycles. Using this pump in a continuous duty application by manipulating the switch to stay on, will effect th

Wayne EFL30

Downloads : 0 Arquivo Tamanho: 256 kb    Fabricante : Wayne  
Categoria : Canalização

Low line voltage 2. Debris caught in impeller or discharge 3. Worn or defective pump parts or plugged impeller 4. Pump running backwards 5. Pump not properly sized for application 6. Check valve stuck closed or installed backwards 7. Shut off valve closed 1. If voltage is under recommended minimum, check wiring size from the main switch on property. If OK, contact power company 2. Remove, clean and check for tightness 3. Replace entire pump. Clean parts if required 4. Check rotation. (CCW from b