Log:
Sort : Nome ↑   Downloads   Avaliação   Tamanho ↑  

Wayne SEP5

Downloads : 2 Arquivo Tamanho: 835 kb    Fabricante : Wayne  
Categoria : Canalização

All models with a plug-in power cords system should still have a qualified electrician inspect the outlet being used to ensure proper wiring. Grounding Grounded Blade Outlet Power Cord Switch Cord Figure 3 TESTRESET The control switch is a wide-angle system which prevents short cycling of the pump motor and the consequential problems that short cycling can cause. The switch can be mounted on the discharge pipe (just above the pump discharge flange). See illustrations for switch mounting arrangem

Wayne ESP15

Downloads : 42 Arquivo Tamanho: 861 kb    Fabricante : Wayne  
Categoria : Piscinas

5. A single thirty-second tone will sound when power to the system is interrupted. The unit will reset automatically when power is restored. A three-second tone will sound every time the pump starts. Troubleshooting Chart Maintenance Always disconnect the electrical supply before attempting to install, service, relocate or perform any maintenance. If the power source is out of sight, lock and tag in the open (off) position to prevent unexpected power application. Failure to do so could result in

Wayne P265

Downloads : 3 Arquivo Tamanho: 244 kb    Fabricante : Wayne  
Categoria : Greeley

The pressure should be neutral at the center. Closing the adjuster lowers the neutral pressure point and opening the adjuster raises the neutral pressure point. Once the neutral pressure point has been adjusted, the combination air shutter should be adjusted so that the percent CO2 test must be made at the inlet side of the draft hood. If the CO2 reading is not within the recommended limits, then the combustion air shutter should be re-adjusted and then the neutral pressure point be rechecked an

Wayne WLS100

Downloads : 2 Arquivo Tamanho: 265 kb    Fabricante : Wayne  
Categoria : Ferramentas para Jardim

Safety Guidelines This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols. Danger indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Warning indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Caution indicates a potentiall

Wayne DSP60

Downloads : 6 Arquivo Tamanho: 275 kb    Fabricante : Wayne  
Categoria : Canalização

Faulty float switch 1. Install check valve 2. Replace float switch 3. Check valve not installed or leaking 3. Remove and examine check valve for proper installation and free 4. Discharge head is less than operation manufacturer's minimum 4. Recheck all sizing calculations to determine proper pump size Pump shuts off and turns 1. Excessive water temperature 1. Pump should not be used for water above 120° on independently of 2. Defective switch or entangled switch 2. Replace or reposition pump swi

Wayne 351301-001

Downloads : 0 Arquivo Tamanho: 121 kb    Fabricante : Wayne  
Categoria : Canalização

Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. Submersible Utility Pump Description This portable, submersible utility pump is designed for non-automatic use in water. The units are equipped with an 8 ft. 3-prong grounding type power cord. The motor is oil filled and sealed for cooler operation. The discharge fitting is designed for convenient at

Wayne 331400-001

Downloads : 2 Arquivo Tamanho: 256 kb    Fabricante : Wayne  
Categoria : Canalização

The pump motor is equipped with automatic resetting thermal protector and may restart unexpectedly. Protector tripping is an indication of motor overloading as a result of operating the pump at low heads (low discharge restriction), excessively high or low voltage, inadequate wiring, incorrect motor conditions, or a defective motor or pump. 14. This pump is designed to transfer water in cycles. Using this pump in a continuous duty application by manipulating the switch to stay on, will effect th

Wayne P250AF-DI

Downloads : 0 Arquivo Tamanho: 244 kb    Fabricante : Wayne  
Categoria : Greeley

in. (645.2 mm2) for each directly to outdoor air. 1,000 Btu (.2931 kW) (.2931 kW) per hourper hour input. Attic Ventilation Louvers are required at each end of attic with alternate air inlet No. 1. 1, 2, and 3 mark alternate locations for air from outdoors. Free area shall be not less than 1 Sq. in. (645.2 mm2) per 5,000 Btu (.1.465 kW) per hour of the total per hour of the total input rating of all appliances in the enclosure. Crawl-space Ventilation Louvers for unheated crawl space are require

Wayne P250AF-EP

Downloads : 0 Arquivo Tamanho: 244 kb    Fabricante : Wayne  
Categoria : Greeley

(1121Pa) for natural gas and 11.0” w.c. (2740Pa) for L.P. gas; the maximum gas supply pressure is 10.5: w.c. (2615Pa) for natural gas and 13” w.c. (3238Pa) for L.P. gas. P250 ONLY Input BTU/Hr. (kW/Hr.) Floor Area Sq. Inches (mm2) Preferred Width and Length (mm) Recommended Minimum Wall Thickness Recommended Minimum Floor Construction 50,000 (14.65) 49 (31610) 7(177.8)x7 (177.8) 2 1/2” (63.5mm) insulating firebrick plus back up of 1 1/2” (38.1mm) or more loose insulation. 2 1/2” (63.5mm) Insulat

Wayne 330102-001

Downloads : 2 Arquivo Tamanho: 880 kb    Fabricante : Wayne  
Categoria : Canalização

Defective float switch 1. Replace float switch off 2. Float switch movement restricted 2. Reposition pump or clean basin as required to provide adequate clearance for float 3. Restricted discharge (obstruction in 3. Remove pump and clean pump & piping piping) 4. Excessive inflow or pump not properly 4. Recheck all sizing calculation to determine proper pump size sized for application Pump operates but delivers little or no water 1. Low line voltage 2. Debris caught in impeller or discharge 3. Wo





categorias