Log:

Hunter Fan 82022

Downloads : 0 Arquivo Tamanho: 13 mb    Fabricante : Hunter Fan  
Categoria : Fans

If you have questions, contact the manufacturer at the phone number or address listed in the warranty. 2. Before installing, servicing, or cleaning the unit, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely attach a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by qualified person(s) in accord

Hunter Fan LA STRADA 82022

Downloads : 14 Arquivo Tamanho: 13 mb    Fabricante : Hunter Fan  
Categoria : Fans

7. Install fan at least 5 feet (1.52 m) above the floor. 8. Never place a switch where it can be reached from a tub or shower. 9. This unit must be grounded. E F G H I J M N O x4 * * * NOTE:Strain relief cable connector must be installed. Not Included. A B C 95044-01-096 95029-01-000 77481-01-000 03242-01-232 95491-06-000 74508-03-133 97258-01-000 65219-01-000 77521-01-000 75184-01-092 97260-01-000 P 76079-02-481 x2 D Extra Screws K L 3/8” Cable Connector 3 1 Turn off the power source. Tools Nee

Hunter Fan BELLE MEADE 82023

Downloads : 0 Arquivo Tamanho: 11 mb    Fabricante : Hunter Fan  
Categoria : Fans

If ducting does not fit securely, an adapter may need to be purchased. Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. 42950-01 04/18/2007 6 A19J A20 0000IA18 0000A17 ONOFFA21 A22E1Go to stepon page 17 to attach grille. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. Connect wiring harness. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRI

Hunter Fan 81021

Downloads : 8 Arquivo Tamanho: 10 mb    Fabricante : Hunter Fan  
Categoria : Fans

Turn on the power source. D23 Go to step on page 18 to attach grille. E1 E1 E2 L K Remove the thumbscrews. Connect wiring harness. E4 E3 J K Remove the strain relief bracket screw. Position the strain relief bracket under the motor as shown. E6 E5 Align posts A, B, C and D (stamped into motor housing) with posts A, B, C and D (stamped into light fixture). Slide light fixture over posts. Insert the strain relief bracket’s dog-leg tab so that it hooks over the lip of the motor. Reinstall the strai

Hunter Fan 43041-01

Downloads : 30 Arquivo Tamanho: 10 mb    Fabricante : Hunter Fan  
Categoria : Fans

If you have questions, contact the manufacturer. 2. Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. when the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including

Hunter Fan 81030

Downloads : 0 Arquivo Tamanho: 10 mb    Fabricante : Hunter Fan  
Categoria : Fans

To obtain servicing, contact the nearest Hunter authorized service center of the Hunter Fan Company Service Department, 2500 Frisco Avenue, Memphis, Tennessee 38114. Please contact us before shipping your bath exhaust fan to us. If we authorize you to ship it to us, you will be responsible for all insurance and freight or other transportation charges to our factory or service center. We will return your Hunter bath exhaust fan freight prepaid. Your Hunter bath exhaust fan should be properly pack

Hunter Fan ELLIPSE 90063

Downloads : 0 Arquivo Tamanho: 9 mb    Fabricante : Hunter Fan  
Categoria : Fans

Use this unit only in a manner intended by the manufacturer. such as those published by the National Fire Prevention If you have questions, contact the manufacturer at the phone Association (NFPA), and the American Society for Heating, number or address listed in the warranty. Refrigeration and Air-Conditioning Engineers (ASHRAE), and the local code authorities. 2. Before installing, servicing, or cleaning the unit, 5. When cutting or drilling into wall(s) or ceiling, do not disconnect the power

Hunter Fan ELLIPSE 90064

Downloads : 0 Arquivo Tamanho: 9 mb    Fabricante : Hunter Fan  
Categoria : Fans

Tighten screws. Connect 4” duct and vent to the outside. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. Pull wires through the strain relief. 13 Tighten the strain relief screws. 41722-01 3/29/2006 41722_EngS_3.29.03.indd 13 3/29/06 10:55:07 PM C23 F 1 2 A 3 Pin 2 Pin Fan Motor Light Light Green Black Black Red Red White Black Black White White Bare Copper Ground C22 Night Light Night Light Switch 1 (AC In) Main Switch 1 (AC In) *Option Fan & Main Light Toget

Hunter Fan 83003

Downloads : 3 Arquivo Tamanho: 8 mb    Fabricante : Hunter Fan  
Categoria : Fans

DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. I B23 Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. B25 Turn on the power source. ON OFF B26 B24 J Test the motor. If the motor does not run, check the plug connection. Secure the motor by tightening the 2 screws. 023_41953_EngS_2-15-08.indd 10 2/16/08 12:25:36 PM C12EFExisting Construction – accessible from above EXISTING FAN C11 NO EXISTING FA

Hunter Fan 41953-01

Downloads : 5 Arquivo Tamanho: 8 mb    Fabricante : Hunter Fan  
Categoria : Fans

0 A17 0 I A18 ON OFF A21 Test the motor. If the motor does not run, check the plug connection. A22 E1 Go to step on page 17 to attach grille. 023_41953_EngS_2-15-08.indd 7 2/16/08 12:25:32 PM 41953-01 02/15/2008 Slide the mounting rails into brackets. Mark position of screws by using holes as a template. Insert screws, leaving space between the screw head and the joist. Screws are not provided. B11 E F 5/8 1/2 5/8 1/2 B12 1/8” bit B14 B15 B16 F B13 Position the correct depth mark at the bottom e





categorias