and and H/AT100R Installation Guide H/AT120R PN: LTP0010 01/30/04 Also Applies to: XL100R XL120R Models: ATTENTION INSTALLER: THIS DOCUMENT IS PURCHASER’S PROPERTY AND IS TO REMAIN WITH THE HEAT PUMP OWNER (Text Box comment AQ Tech, 9/24/04) NOTES TABLE OF CONTENTS WELCOME TO THE TEAM -------------------------------------------------------5 IMPORTANT FEATURES OF YOUR NEW HEAT PUMP -------------------6 SAFTEY INFORMATION ----------------------------------------------------------7 QUICK START & ST
If you utilize a time clock or similar device to control the operating time of your pool system, you should temporarily override the device and allow it to run the pool or spa pump until the water reaches the desired temperature. Your heat pump is a maintainer of heat and is sized to overcome the heat loss during the coldest period in which you are trying to heat. Once your pool is up to temperature, the time clock can be reset. The time your system has to run may need to be extended during the
Risk of Electrical Shock… Ensure all electrical power to the heater has been disconnected prior to removing the heater front access panel. Leave electrical power disconnected throughout the following jumper repositioning procedure. 1. To access the jumper, disconnect electrical power and remove the heater front entry panel; then, remove the metal cover from heater electrical enclosure. For layout details of the PC control board, see figures on next page. 2. Locate the mode jumper in the upper ri
H. Return system controls to desired mode of operation. 6. Spa Dead Band Differential [dBS]: In the heating mode, the dead band differential determines the number of degrees the water temperature must fall below the set point before the thermostat closes. In the cooling mode, the dead band differential determines the number of degrees the water temperature must rise above the set point before the thermostat closes. When in the auto-changeover mode, the dead band differential operates in the same
Since 1981, AquaCal has maintained the worldwide lead in the manufacture of swimming pool & spa heat pumps. Your new heat pump is not only a great investment, but also the most cost effective method available for heat-“You can rest assured ing pools and spas. For example, your knowing your new heat heat pump is up to 400% more efficient than gas, and, when compared to elec pump is of the highest tric resistance heat, your heat pump is nearly 600% more effective. You can rest quality and efficien
EQUIPMENT CLEARANCES Keep the area immediately adjacent to the heat pump clear of items such as shrubs and bushes, lawn furniture, chemicals containers, etc. These items can prevent air from circulating properly through the heater, and will result in inefficient operation and/or damage to the heat pump. Figure 1 Figure 2 Overhang with Gutter 5 feet Minimum Clearance Overhead Rain Run-Off Must Be Directed Away From Heater (Front) 30” Minimum Clearance (Rear) 12” Clearance for all IceBreaker / Hea