American Sensor 770LBX

Downloads : 86 Arquivo Tamanho: 130 kb    Fabricante : American Sensor  
Categoria : Alarme de incêndio

Interconnect units within a single family residence only. Otherwise all households will experience unwanted alarms when you test any unit in the series. Interconnected units will only work if they are wired to compatible units and all requirements are met. The wiring shall be in accordance with the provision of Articles 210 and 3003 (B) of the National Electrical Code, ANSI/NFPA 70. The resistance of the interconnecting wiring shall be a maximum of 10 ohms. This unit is designed to be compatible

American Sensor CB100

Downloads : 50 Arquivo Tamanho: 352 kb    Fabricante : American Sensor  
Categoria : Alarme de incêndio

CB100 INSTRUCTION MANUAL Page 1 This manual contains instructions for installing your American Sensors™ relay module. The relay module is ULC listed as an accessory for use only with American Sensors™ interconnectable smoke alarms in the 470L, 670L and 770L series, plus models SA360, SA379, ESA5011 and combination CO/Smoke alarm model C0S2010. WARNING: This relay will not operate without continuous AC power. Do not use with battery backup units. CAUTION: Do not interconnect Model No. CB100 t

American Sensor LP405A

Downloads : 22 Arquivo Tamanho: 315 kb    Fabricante : American Sensor  
Categoria : Alarme de incêndio

THIS DEVICE IS NOT SUITABLE FOR INSTALLATION IN A HAZARDOUS LOCATION, AS DEFINED IN THE NATIONAL OR CANADIAN ELECTRICAL CODE. Introducing the LP401, LP401A, LP405, LP405A Propane Gas Detector The LP401, LP401 A, LP405, LP405A Propane Gas Detectors are effective products for detecting any build-up of propane gas in your home. Dicon Global Inc., the maker of these propane gas detectors, has been developing and making products for detecting gases since 1985. Your new detector: • Is easy to inst

American Sensor ESA5010

Downloads : 11 Arquivo Tamanho: 69 kb    Fabricante : American Sensor  
Categoria : Alarme de incêndio

ground fault interrupter. It is highly recommended that smoke 3. Press and hold the test button until the alarm sounds. NOTE: It lightning, children playing with matches, or arson. • In the center of a room or hallway: As it is impossible to predict alarms be wired on a separate circuit (one with no other lights or may be necessary to press the test button for up to 20 seconds for anthe source of a fire. If it is necessary to place the alarm on a wall, appliances) to ensure maximum reliability o

American Sensor ESA5011

Downloads : 10 Arquivo Tamanho: 145 kb    Fabricante : American Sensor  
Categoria : Alarme de incêndio

Determine that the initiating alarm triggers other alarms in the violent explosions, escaping gas, improper storage of flammable next alarm. wire. NOTE: The SA360 and ESA5011 are interconnectable system. with up to 11 other units. materials, overloaded electrical circuits, natural causes such as • In the center of a room or hallway: As it is impossible to predict 7. Model ESA5011: Pressing the test button activates the relay. lightning, children playing with matches, or arson. the source of a fi

American Sensor SA379

Downloads : 9 Arquivo Tamanho: 391 kb    Fabricante : American Sensor  
Categoria : Alarme de incêndio

This smoke alarm is also interconnectable with up to 11 other units. Important information about your smoke alarm € Install alarms outside of every bedroom area and on every floor of your home. Please refer to Section 3 •Where to Locate Smoke AlarmsZfor details. € Install the alarm as close as possible to the center of the ceiling. € Your Smoke Alarm is packaged with the back-up battery reversed. Connect it before mounting the unit. Ensure proper polarity of the battery. Alarm will •beepZif batt

American Sensor 120 VAC HARDWIRE SA379

Downloads : 7 Arquivo Tamanho: 83 kb    Fabricante : American Sensor  
Categoria : Alarme de incêndio

WHERE TO LOCATE SMOKE ALARMS WARNING ! This smoke alarm is suitable for residential Alarm-Pause® period, the smoke alarm should “beep” DICON GLOBAL INC. SHALL HAVE NO basement smoke alarm may not detect a fire which started on use. It is not to be connected to a approximately once every 45 seconds to alert the household that LIABILITY FOR ANY PERSONAL INJURY OR PROPERTY As a minimum, smoke alarms should be located between the first or second floor. commercial or industrial fire alarm panel. the

American Sensor LP401A

Downloads : 4 Arquivo Tamanho: 315 kb    Fabricante : American Sensor  
Categoria : Alarme de incêndio

It is normal for this light to turn on once or twice after you power the detector or after a power failure. A G What should you do if the ALARM sounds? EVACUATE IMMEDIATELY! Do a head count to check that everybody is accounted for. Call the nearest fire department and ask them to determine the source of propane gas. Do not re-enter the premises until the problem has been corrected and the propane gas has been dispersed. ! WARNING: Activation of this device indicates the presence of propane g

American Sensor CO920

Downloads : 4 Arquivo Tamanho: 466 kb    Fabricante : American Sensor  
Categoria : Alarme de incêndio

This will silence the alarm for up to 6 minutes. If the unit re-alarms after reset it confirms the ongoing presence of harmful levels of carbon monoxide. I. How can you replace your back-up battery? How to replace the battery 1. Unplug alarm from outlet; battery is at the bottom on back of unit 2. Push battery to left to remove from plastic spring 3. Remove existing 9 volt battery 4. Insert fresh 9 volt battery into terminals. Push battery and wires back into enclosure. Use only recommended batt

American Sensor CO910

Downloads : 2 Arquivo Tamanho: 466 kb    Fabricante : American Sensor  
Categoria : Alarme de incêndio

Exposure Times The carbon monoxide concentrations and time standards for the alarms are as follows: The Full Alarm Activates • Within 60–240 minutes at exposures of 70 ppm • Within 10–50 minutes at exposures of 150 ppm • Within 4–15 minutes at exposures of 400 ppm WARNING: O. Warranty Information 5 Year Limited Warranty Dicon Global Inc., which manufactures American Sensors Carbon Monoxide Alarms, warrants its product, to the original consumer purchaser, to be free from defects in material and w