Log:
Sort : Nome ↑   Downloads   Avaliação   Tamanho ↑  

Bacharach 21-7012

Downloads : 20 Arquivo Tamanho: 288 kb    Fabricante : Bacharach  
Categoria : Alarme de incêndio

It will probably be necessary to apply store lubricant to the Cup, revrap, and repeat the procedure several tine» before a satisfactory thin, even filn renains. Do not apply too nuch lubricant or seepage vill result vben TRUE-SPOT is stored. After Cylinder bore is lubricated; vork lubricant renaining on uuslin cloth onto outer rim of Cup and reassemble TBDE-SPOT. Parts List for TRUE-SPOT® Smoke Tester (21-7012) 1. laeberaeh Xaeorporete4 nrrati to btjw thet at fib* tiae of 4«livery this ptoSe

Bacharach 2072-0400

Downloads : 18 Arquivo Tamanho: 1 mb    Fabricante : Bacharach  
Categoria : Aparelhos de ar condicionado

A red light on top of the unit flashes whenever a process is complete or when the unit needs attention from the technician. The MAC2000 is ETL listed to UL standards and meets SAE specifications for recycled refrigerant. 1.1 Glossary of Terms A/C Air conditioner or air conditioning A/C System The vehicle’s air conditioning system Unit The MAC2000 itself Screen LCD Display Contaminated Refrigerant that has been mixed with some other type of refrigerant. 1.2 General Operating Guidelines • The MAC2

Bacharach KN-COPE-I

Downloads : 15 Arquivo Tamanho: 208 kb    Fabricante : Bacharach  
Categoria : Alarme de incêndio

For your convenience, write down the following information. If you call our consumer hotline, these are the first questions you will be asked: Alarm Model Number (located on back of the alarm): Date of Manufacture (located on back of the alarm): Date of Purchase: Where Purchased: ATTENTION: Please take a few minutes to thoroughly read this user’s guide which should be saved for future reference and passed on to any subsequent owner. Manual P/N 820-1669 Rev. A What To Do When The Alarm Sounds! WA

Bacharach HGM300

Downloads : 15 Arquivo Tamanho: 652 kb    Fabricante : Bacharach  
Categoria : Alarme de incêndio

Locate the second reset button to the left of the CPU reset button. Hold the left button in, press and release the CPU reset button. There will be 5 beeps (beep/beep – beep/beep – beep). Release the left button. The monitor will now be reset A second way to reset the HGM300 CPU is to turn off power, press and hold the left hand reset button and re-apply power – 5 beeps and release button. RDM800 CPU RESET Shut off power to the RDM800, press and hold the top right adjacent button and re-apply pow

Bacharach The Informant Dual Purpose Leak Detector

Downloads : 14 Arquivo Tamanho: 599 kb    Fabricante : Bacharach  
Categoria : Alarme de incêndio

The refrigerant sensor tip is finely tapered to 0.2" diameter - so you can get in between coils and fittings, gaining access to hard to reach areas. The Informant™ 2 leak detector features an audible indicator with a mute option coupled with sequential LEDs to monitor increasing concentrations of refrigerant or combustible gases. Dual bar graph displays offer visual confirmation no matter what position the instrument is in. And, a flashing light at the tip of the probe helps to visually define

Bacharach KN-COB-B-LS (900-0233)

Downloads : 13 Arquivo Tamanho: 242 kb    Fabricante : Bacharach  
Categoria : Alarme de incêndio

This alarm has not been investigated for carbon monoxide detection below 70 PPM. Contents of This User’s Guide 1. Information About Carbon Monoxide 2. Product Features and Specifications 3. Installation Locations 4. Installation Instructions 5. KN-COB-B-LS Operating Characteristics 6. KN-COPP-B-LS (with digital display) Operating Characteristics 7. Alarm Characteristics 8. Maintenance 9. Limited Warranty 1. Information About Carbon Monoxide General Carbon Monoxide Information Carbon monoxide is

Bacharach Stinger

Downloads : 13 Arquivo Tamanho: 8 mb    Fabricante : Bacharach  
Categoria : Aparelhos de ar condicionado

(0.13kg/min.) Liquid Recovery Rate: 3.53lbs./min. (1.60 kg/min.) Liquid Push / Pull: 12.28lbs./min. (5.58 kg/min.) Refrigerant134a Vapor Recovery Rate: 0.22lbs./min. (0.10 kg/min.) Liquid Recovery Rate: 2.66lbs./min. (1.21 kg/min.) Liquid Push / Pull: 10.96 lbs./min. (4.98 kg/min.) Refrigerant410aVapor Recovery Rate: 0.22lbs./min. (0.10 kg/min.) Liquid Recovery Rate: 3.00lbs./min. (1.37 kg/min.) Liquid Push / Pull: 14.58lbs./min. (6.63 kg/min.) Auto80%TankOptional Shut-OffWeight24 lbs. (11 kg) S

Bacharach Monoxor III

Downloads : 10 Arquivo Tamanho: 720 kb    Fabricante : Bacharach  
Categoria : Alarme de incêndio

with batteries Dimensions 7.5"H x 3.1"W x 2.1" D (190mm x 79mm x 53mm) Warranty 2 years, including sensor ORDERING INFORMATION PART N0. DESCRIPTION 19-8104 Monoxor® III includes 4 AA batteries, probe and hose assembly with integral water-trap / filter, and hard carrying case 19-8105 Monoxor® III Kit, includes 4 AA batteries, probe and hose assembly with integral water-trap / filter, and a hard carrying case, plus an IrDA printer and a roll of printer paper 24-1400 IrDA Printer with Dispo

Bacharach Fyrite INSIGHT

Downloads : 9 Arquivo Tamanho: 1 mb    Fabricante : Bacharach  
Categoria : Alarme de incêndio

2008 Product Leadership • Training • Service • Reliability F1 F2 F3 RUN ESC HOLD PWR W ARRANT Y Bacharach, Inc. warrants to Buyer that at the time of delivery this Product will be free from defects in mater ial and manufac ture and will conform substan tially to Bach arach Inc.’ s ap plicable spec i fi ca tions. Bacharach’s li a bil i ty and Buyer’s remedy under this warranty are lim it ed to the repair or replacement, at Ba charach’s option, of this Product or parts thereof returned to Seller a

Bacharach Gas Leak Detection

Downloads : 9 Arquivo Tamanho: 192 kb    Fabricante : Bacharach  
Categoria : Alarme de incêndio

On the lookout for leaks.On the lookout for leaks. In the field, the Gas In the field, the GasIn the field, the Gas Hunter HunterHunterdoes the job of seven individual does the job of seven individualdoes the job of seven individual instruments to optimize technician efficiency in leak survey operations instruments to optimize technician efficiency in leak survey operationsinstruments to optimize technician efficiency in leak survey operations and customer service calls. It is able to sniff out





categorias