Se incluyen instrucciones en Espanol y Frances. Directives en francais et en espagnol compris. LU ®CLU ® SAVE THE ENVIRONMENT RECYCLE APPROPRIATE MATERIALS Patents: 5,037,583; 5,110,511; 5,133,904 Other Patents Pending Printed in U.S.A To order parts and accessories call 1-800 547-3888 586 4180 Rev.5/04 Introduction Today, airtight homes have helped conserve energy compared to just a few years ago. Unfortunately, along with this improvement came an increase in indoor pollution and contaminants.
* * * * 19. Pulley, Motor / Polea Del Motor ............................................................ ............. * * * * 20. Electrical Cord, Motor (115V) / Cable Eléctrico Del Motor (115V)...... ............. 110372 110372 110372-1 110372-1 20. Electrical Cord, Motor (230V) / Cable Eléctrico Del Motor (230V)..... ............. 110372-2 110372-2 110372-2 110372-2 21. Shaft, Blower Wheel / Eje De La Rueda ................................................ .............110183 110183 110183
0 CFM RPM 75/85 SD 95 SD 10/12 SD 14/21 SD CS 11/16 MODEL NO. Performance Tables above Power rating include drive Performance motors with CFM INCHES STATIC PRESSURE CFM INCHES STATIC PRESSURE 6868 420 6724 424 Champion Commercial Aspen Cooler Specifications Down DischargeDown Discharge Down DischargeDown Discharge Side DischargeSide Discharge Side DischargeSide Discharge Champion Cooler certifies that the evaporative air coolers shown here are licensed to bear the AMCA Seal. The ratings shown ar
Digital Control . Automatic Humidistat . Automatic Shutoff . Quiet Setting for Nighttime use C SAVE THE ENVIRONMENT RECYCLE APPROPRIATE MATERIALS To order parts and accessories call 1-800-547-3888 French and Spanish Instructions included. Se incluyen instrucciones En Espanol y Frances. Directives en Francais et en espagnol compris This product uses 2 # 1040 Wicks APARTMENT, Tower Style Evaporative Humidifier General Safety Instructions READ BEFORE USING YOUR HUMIDIFIER DANGER: means if the safet
REMOVING SCALE 6) Carefully lift wick from cabinet, allowing any water to drain from it into water channel. Place in sink or tray to finish draining. 7) Remove any remaining water in channel with a sponge. Fill water channel with one 8 oz. cup of undiluted white vinegar. Let solution stay 20 minutes. Remove with a sponge. Clean all interior surfaces with soft brush. Dampen soft cloth with undiluted white vinegar and wipe out water channel to remove scale. 8) Rinse water channel thoroughly with f
Using no harmful chemicalsno harmful chemicals & much less electricity than traditional air conditioning, evaporative coolers provide the energy efficient cooling alternative. Champion’s Aspen Coolers use a time-tested technology that has been shown to be exceptionally effective in hot, dry climates. These American-madeAmerican-made units are made of heavy duty steel and high qualty components. Your maintenance team will appreciate that repair is easily facilitated by the removable louver panels
Bolts together for easy access and rust/corrosion resistence Blower - Machine balanced for smooth, quiet operation and maximum air delivery Pump - Permanently lubricated bearings can run with or without water Built-in leveling leg - Window units include house legs for leveling and extra support * Except for N28W unit that set our coolers above the rest Selecting the right Essick cooler is EASY 1. Consult zone map to find correct size. 2. Consult table below to find correct "minutes per a
For maximum safety, make sure cooler cabinet is properly grounded to a suitable ground connection. Cooler must be connected to proper line current, voltage and cycle, as stamped on cooler motor and pump motor specification plate. Do not allow pump to tip over and become submerged. Always TURN OFF POWER before performing any mainte- Operation For the best cooling performance, if the pads are dry, pre-wet the pads by running the pump for a few minutes before starting the blower. These cooler
In the event additional information is desired, your dealer will be more than glad to assist you in every possible way. 6 110503-1 3 Troubleshooting Problem Possible Cause Remedy Failure to 1. No electrical power to 1. Check power start or no air unit delivery • Fuse blown • Replace fuse • Circuit breaker tripped • Reset breaker • Electric cord unplugged • Plug in cords or or damaged replace if damaged 2. Belt too loose or tight 2. Adjust belt tension 3. Motor overheated 3. De
222130-063 222130-063 222140-046 222140-046 9. Back Post, Right / Poste Trasero, Derecho ........................................................ . 222130-064 222130-066 222140-047 222140-049 10. Back Post, Left / Poste Trasero, Izquierdo ......................................................... . 222130-065 222130-067 222140-048 222140-050 11. Blower Housing / Caja De La Rueda................................................................. .324130-202 324130-202 324140-202 324140-202 12. C