Therefore, immediate response to a fire is imperative. The main objective of fire detection control panel Series BC216 is to alarm and to react in time and, consequently, save lives and protect property. For decades LST have focused their aims to undertaking unrivaled efforts in order to realize new innovations in the security area. Research, development and production are loca- The fire detection control panel BC216–1S is designed to be used in small systems with only one ADM loop. It comprises
The modern design of the sensing chamber allows to reliably evaluate the characteristics of fire. The proven ADM loop technology with Apollo/Discovery protocol establishes a permanent communication between the fire detection control panel and the detector. That ensures a periodical function testing of the detector. In the control panel all types of fires are detected by continuously comparing fire patterns. Specifications Supply through loop voltage Current consumption typ. 340|jA (quiescent)
Neither juridical responsibility nor any kind of liability is taken for eventually remaining incorrect information. Labor Strauss Sicherungsanlagenbau Ges.m.b.H. reserves the right to change information without notice and thereby does not take any liability. The pointing out of possible errors in the manual will be gratefully accepted by the authors. All brand names and product names used in this manual are trade names, sevice marks, trademarks, or registered trademarks of their respective owner
It complies with Class A2S and can be used up to a room height of 6m. Addressable conventional technology is used for alarm transmission to the fire detection control panel. The detector addressing can be achieved in 2 ways: • A detector with an Address Module NG58-1 can be individually identified by the suitable control panel. • An address, which has been stored in the detector by means of the Remote Programming and Test Unit, is displayed on the Zonal Display Unit S300ZDU Specifications
Therefore, it is extremely well suitable for the detection of fires which are difficult to detect with common smoke detectors - for example, alcoholic fires or gas flames. The detector is ideal for the following applications: • Pharmaceutical industry • Paint shops • Warehouses • Nuclear facilities • Tunnels three independent infrared sensors for different wavelengths and with an intelligent evaluation logic, the detector can safely distinguish between alarm situations and deceptive alarm
Building Security. A mechanical theft protection of the detector can optionally be activated at the detector base. The Detector Base B501DG is 6mm higher than the Detector Base B501, and is therefore suitable for thick cables. It has the same height as the Isolator Detector Base B524IEFT-1. © I^BOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52H4-0 • FAX +43 1 52114-27 OFFICE@LST.AT • WWW.LST.AT • ALL RIGHTS RESERVED B501 DBL LST EN 0804.PDF • PAGE 1
Due to its robust multi-wire screw terminals, the detectors can be wired with ease, thus achieving a secure and durable connection. The base provides the possibility to easily connect an external remote indicator, and has been designed for surface mounting in dry rooms. For special applications a range of accessories (for moist room, false cei- ling or flush installation) is available Specifications Ambient temperature -30°C to +70°C Relative humidity 0 - 95% (no condensation) Colour crea
Therefore, immediate response to a fire is imperative. The main objective of the fire detection control panel Series BC216 is to alarm and to react in time and, consequently, save lives and protect property. For decades LST have focused their aims to undertaking unrivaled efforts in order to realize new innovations in the security area. Research, development and production are loca- The Fire Detection Control Panel BC216-1CE is a modularly designed compact control panel in 19“ slide-in technolog
The transmitter/receiver unit projects a pulsed infrared light beam through the area to be protected towards a reflector, which returns the light beam. The smoke detection is based on the attenuation of the light beam by means of smoke. The detector uses intelligent evaluation algorithms to compensate for the influence of contamination of the optical measurement system. With that, the response sensitivity of the detector is kept constant for a long time - an effective step to avoid false alarms
The modern design of the sensing chamber allows to reliably evaluate the characteristics of fire. Due to the high sensitivity of the laser detection chamber, the detector is ideal for applications where an early fire detection is crucial: • Computer rooms • Clean room manufacturing • Hospitals • Aspiration smoke detection systems Depending on the application, the high sensitivity of the detector is individually adjustable in 9 steps between 0.03%/m and 3.3%/m and provides a number of speci