3.2 Accessories A wide range of accessories are available for the SP200/210. The list below represents a summary of accessories available at the time this manual was published. For up-to-date listings, and for price and availability, please refer to the current Price Book. Order Code Description Batteries QPA-1350 1350mAh NimH battery. Chargers QPA-1185-2 2-pin (European) Intelligent fast charger with mains adapter QPA-1185-3 3-pin (UK) Intelligent fast charger with mains adapter QPA-1185 Spare
Issue 1.0 SPARE PARTS & MAINTENANCE POLICY 03/01 Page 10-1 Maxon SP200/210 Radio SP200/210 10.1.1 Component Replacement Surface mount components Surface mount components should always be replaced using a temperature controlled soldering system. The soldering tools may be either a temperature controlled soldering iron or a temperature controlled hot-air soldering station. A hot-air system is recommended for the removal of components on the multi-layered boards used in the radio. With either solde
© 2008 Copyright Maxon Corporation. All rights reserved. 1-2.3-21 Low temperature burners -INDITHERM® E-m-7/08 Start-up instructions for INDITHERM® burners Instructions provided by the company or individual responsible for the manufacture and/or overall installation of a complete system incorporating MAXON burners take precedence over the installation and operating instructions provided by MAXON. If any of the instructions provided by MAXON are in conflict with local codes or regulations, please
This appliance is not convertible for use with other gases, unless a certified kit is used. B-VENT MPB-33/35/40/45 SERIES B-VENT GAS FIREPLACES P/N 850,033M REV. B 05/2006 MODELS Millivolt Models Electronic Models MPB3328CNM MPB3530CPM MPB3328CNE MPB4035CNE MPB3328CPM MPB4035CNM MPB3530CNE MPB4540CNE MPB3530CNM MPB4540CNM A French manual is available upon request. Order P/N 850,033CF Ce manuel d’installation est disponible en francais, simplement en faire la demande. Numero de la piece 850,033CF
HHV - sg = 0.6 [1] Combustion air: 15° C - 21 % O2 - 50 % humidity - sg = 1.0 [1] Stated pressures are indicative. Actual pressures are a function of air humidity, altitude, type of fuel, and gas quality. Burner size & type 100 300 550 700 850 1100 1500 1800 back pressure [2] mbar Max. capacity [3] kW (HHV) 0 125 340 550 720 850 1050 1472 1800 1.5 110 285 500 675 775 880 1266 1693 Min. capacity [4] kW (HHV) 0- 1.5 5.0 6.0 10 15 15 25 25 25 Pilot capacity [5] kW (HHV) 0-1.5 7.5 10.0 15 25 25 40 4
All burners are available in ANSI and ISO version. Each version will have the main gas inlet connection following either NPT or ISO standards. All burners include an adjustable orifice needle valve for pilot flame fine tuning, provision for UV-scanner connection and a stainless steel combustion sleeve. Options Every burner has a set of options available, according to the table below: HTS High temperature discharge sleeve FLR Combustion air filter box, recommended in extremely dusty surroundings
• Close the pilot gas valves. • Release to modulation (allow modulation of the burner). • Above sequences shall be completed to include all required safety checks during the start-up of the burner (process & burner safeties). .com combustion systems for industry MAXON reserves the right to alter specifications and data without prior notice. © 2008 Copyright Maxon Corporation. All rights reserved. 1-2.3-11 Low temperature burners -INDITHERM® E-m-7/08 Flame supervision Flame supervision can be acc
Do not bypass any of these safety interlocks, this will result in unsafe operation. • Checks during and after start up During and after start-up, check the integrity of the system. Check all bolted connections after first firing (first time on tempera ture) and retighten if necessary. • Purge For safety reasons, it is required to purge the installation sufficiently long to ensure that all possible combustibles are evacuated before ignition. Refer to the applicable local codes and your specific a
© 2008 Copyright Maxon Corporation. All rights reserved. 1-2.3-15 Low temperature burners -INDITHERM® E-m-7/08 Spark ignitor - SI-1/2 The spark ignitor is standard included with the burner. It is advised to keep at least one additional spark ignitor available as a spare item for maintenance. This spark ignitor can be mounted directly onto the burner spark ignitor connection port. To be used on all burner sizes. See table below for mounting position C depending on burner size. 1) 1/2” NPT Dimensi
.com combustion systems for industry MAXON reserves the right to alter specifications and data without prior notice. © 2008 Copyright Maxon Corporation. All rights reserved. 1-2.3-13 Low temperature burners -INDITHERM® E-m-7/08 INDITHERM® with high temperature discharge sleeve - all sizes 1) Gas inlet 2) Pilot gas connection 3) Combustion air test connection 4) Gas pressure test connection 5) 90° capacity control crank 6) Filter housing (optional) 7) High temperature discharge sleeve 8) Flame su