Log:
Sort : Nome ↑   Downloads   Avaliação   Tamanho ↑  

Field Controls G0573

Downloads : 0 Arquivo Tamanho: 2 mb    Fabricante : Field Controls  
Categoria : Air

Field Controls STARKAP SK-1

Downloads : 2 Arquivo Tamanho: 1 mb    Fabricante : Field Controls  
Categoria : Equipamento de rede

English.......Page 1 Francais.....Page 5 Espanol......Page 8 INSTALLATION REQUIREMENTS 1. Install and secure the vertical vent, gas vent or metal chimney according to manufacturer's instructions or in accordance with NFPA 54 National Fuel Gas code or applicable local codes. The termination of the vertical vent or metal chimney MUST be installed in accordance with the height and roof pitch table (See Figure 1 or Table 1 or refer to NFPA 54 for requirements). These minimum heights may be used if t

Field Controls UV-Aire UV-16/120

Downloads : 6 Arquivo Tamanho: 1 mb    Fabricante : Field Controls  
Categoria : Air

Make sure when installing the base the plated washer on the switch is raised approximately 3.16". The proving switch must be fully engaged. (See Figure 8) 14. With aluminum or foil tape, seal all joints and seams of the plenum near the mounting location to reduce any direct viewing of light. Figure 6 Figure 7 Figure 8 page 6 WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire Air

Field Controls Clearwave Water Conditioner CW-HD-2

Downloads : 1 Arquivo Tamanho: 298 kb    Fabricante : Field Controls  
Categoria : Purificadores de água

With ClearWave™, the electric field generated is always being applied to the water, while a magnetic field relies on the movement of water to produce the electric potential changes. Low frequency waveforms are emitted through two coiled wires attached to the outside of the water pipe. As a result of these waveforms, the two coils are constantly inducing a voltage into the water in the area of the ClearWave™. When one coil induces a positive voltage the other coil induces a counteracting negative

Field Controls Eliminator

Downloads : 0 Arquivo Tamanho: 1 mb    Fabricante : Field Controls  
Categoria : Air

Over a thirty day period, the moisture content was measured at weekly intervals. Homes with the Eliminator installed saw a reduction of moisture levels to as low as 16% and 17%. A wood moisture level of 20% or less is considered ideal. Homes without the Eliminator showed no reduction in moisture content. “The Eliminator performed well, even under severe moisture problem conditions… the amount of air moved is sufficient to correct the problems present.” Cliff Consulting Columbia, S.C. Moisture Co

Field Controls UV-28HPC

Downloads : 4 Arquivo Tamanho: 1 mb    Fabricante : Field Controls  
Categoria : Air

. Approximately 30” OPTIONAL LOCATION 6” Figure 1 WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands. page 3 page 4 WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV

Field Controls UV-28

Downloads : 2 Arquivo Tamanho: 1 mb    Fabricante : Field Controls  
Categoria : Air

Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands. page 6 9. Swing the swivel bracket over the end of lamp. Hand-tighten the wing nut on the stud. Be careful not to over tighten the wing nut. The porcelain at the lamp base may crack when over tightened. (See Figure 17) 10. Plug ballast plug into end of lamp. (See Figure 18) 11. Snap cover onto the unit base. (See Figure 19) 12. Plug the LED wire from the cover onto the

Field Controls UV-28HP

Downloads : 1 Arquivo Tamanho: 1 mb    Fabricante : Field Controls  
Categoria : Air

Be careful not to over tighten the wing nut. 6. Attach ballast plug onto the end of the lamp. 7. Plug in the power cord and press the power switch to the ON position. 8. Press the timer reset button on the circuit board using the eraser end of a pencil or the blunt end of a plastic ink pen. Hold for three seconds. (See Figure 22) 9. Release the timer reset button. The LED on the cover will flash twice, indicating the timer circuit has been reset. 10. Close cover and tighten cover screw. 11. Afte

Field Controls UV-AIRE UV-1500C

Downloads : 0 Arquivo Tamanho: 858 kb    Fabricante : Field Controls  
Categoria : Air

The treatment is a safe, silent, and proven way to make your home or office a healthier place to live and work. SAFETY CONSIDERATIONS WARNING: Never expose eyes or skin to UVC light from any source. • Looking directly at the UVC light may cause permanent eye damage or blindness. • Never operate the UV-Aire Air Purifying System with the UV chamber open. WARNING: DO NOT mount this unit outdoors. • This product is designed for indoor installation only. AFTER OPENING THE CARTON, UNPACK AND INSPECT T

Field Controls RF-1

Downloads : 0 Arquivo Tamanho: 394 kb    Fabricante : Field Controls  
Categoria : Fans

2 Francais .................................. 4 Espanol................................... 6 Page 2 INSTALLATION 1. Install in the door frame between the rooms where the temperature or air moving imbalance exists. Select the corner of the door frame which is closest to an electrical outlet. 2. Using two wood screws, mount the mounting bracket on the door frame 1” from corner. The center of the screw holes should be at least 2” away from the door when it is closed (See Fig.1). 3. Point the fan bl





categorias