Log:
Sort : Nome ↑   Downloads   Avaliação   Tamanho ↑  

Louisville Tin and Stove cdv336b

Downloads : 2 Arquivo Tamanho: 21 kb    Fabricante : Louisville Tin and Stove  
Categoria : Eléctrico

Air Pan Assembly w/Gaskets Gasket, Air Pan Top & Bottom (15-1/4x1) Gasket, Air Pan Sides (25x1) N/A 63 61 62 7420943458 *70074 *70073 $1.20 $27.80 $1.20 $1.20 7420943458 *70074 *70073 $1.20 $27.80 $1.20 $1.20 90 Degree Elbow Vent Terminal Shield Blower Housing w/Motor & Blower Junction Box 56 N/A 46 47 70352 3495070201 43610$10.70 $60.80 $106.60 $4.20 70352 3495070201 43610$10.70 $60.80 $106.60 $4.20 Junction Box Cover Fan Switch 120 degree Cord Set Cover Plate Blower Screen 48 51 N/A N/A 43620

Louisville Tin and Stove RA-094 SERIES

Downloads : 2 Arquivo Tamanho: 1 mb    Fabricante : Louisville Tin and Stove  
Categoria : Eléctrico

Check the damper installation. The damper is not installed. By installing the damper, it will help to eliminate air backflow. 16 DISCLAIMER CAREFULLY INSPECT ALL ITEMS FOR DAMAGES BEFORE ACCEPTING DELIVERY. NOTE ANY DAMAGES ON THE FREIGHT BILL OR EXPRESS RECEIPT. REQUEST NAME AND SIGNATURE OF THE CARRIER’S AGENT AND KEEP COPY TO SUPPORT YOUR CLAIM. Upon acceptance of items, owner assumes responsibility for its safe arrival. Report damages to the carrier and file a claim immediately. Failure to d

Louisville Tin and Stove VFT102

Downloads : 12 Arquivo Tamanho: 416 kb    Fabricante : Louisville Tin and Stove  
Categoria : Eléctrico

Release the gas control knob and it will pop back up. Pilot should remain lit. If pilot goes out, repeat steps 2 thru 7. • If knob does not pop up when released, STOP and immediately call your service technician or gas supplier. • If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier. 9. Turn on all electric power to the appliance. 10. Turn gas control knob counterclockwise to desired temperature setting. TO TURN O

Louisville Tin and Stove WOW403

Downloads : 12 Arquivo Tamanho: 731 kb    Fabricante : Louisville Tin and Stove  
Categoria : Aquecedores a gás

8. Make sure no electrical wires or water pipes are in stud space selected. 9. RESIDENTIAL GARAGE INSTALLATION. Gas utilization equipment in residential garages shall be installed so that all burners and burner ignition devices are located not less than 18 inches {46 cm} above the floor. Unit should be located or protected so it is not subject to damage by a moving vehicle. Use care in selecting a good location within the garage. DO NOT locate the heater where heated air will be directed onto a

Louisville Tin and Stove WOW253

Downloads : 11 Arquivo Tamanho: 731 kb    Fabricante : Louisville Tin and Stove  
Categoria : Aquecedores a gás

Immediately call a qualified service • Do not touch any electric switch; do not technician to inspect the appliance and to use any phone in your building. replace any part of the control system and any • Immediately call your gas supplier from a gas control which has been under water. neighbor’s phone. Follow the gas supplier’s instructions. OPERATING INSTRUCTIONS 1. STOP! Read safety information on this label. 2. Set the thermostat to the lowest setting. 3. Turn off all electric power to the ap

Louisville Tin and Stove HEDV254A

Downloads : 0 Arquivo Tamanho: 176 kb    Fabricante : Louisville Tin and Stove  
Categoria : Eléctrico

For prompt parts service, contact the wholesaler from which you purchased your Cozy heater. NOTE: Parts & schematic drawings on current models are shown at Page 2 SEPTEMBER 2007

Louisville Tin and Stove WOW254

Downloads : 3 Arquivo Tamanho: 731 kb    Fabricante : Louisville Tin and Stove  
Categoria : Aquecedores a gás

• Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. - INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER. WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury

Louisville Tin and Stove BBT53

Downloads : 2 Arquivo Tamanho: 638 kb    Fabricante : Louisville Tin and Stove  
Categoria : Aquecedores a gás

Defective pressure switch. 7. Replace pressure switch. Burner won’t turn off 1. Defective or damaged thermostat wire, or thermostat. 2. Thermostat location. 3. Defective or sticking valve. 4. Excessive gas pressure. 5. Defective or damaged thermostat. 1. Cean be checked by removing wire from control board terminal. If burner goes off, replace thermostat. 2. Re-locate thermostat out of drafts, hot, or cold spots. 3. Replace valve. 4. Contact utility supplying gas. 5. Replace thermostat. Incorrect

Louisville Tin and Stove DVCF407B-R

Downloads : 0 Arquivo Tamanho: 239 kb    Fabricante : Louisville Tin and Stove  
Categoria : Eléctrico

The furnace and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of . psig (3.5kPa). The furnace must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than . psig (3.5kPa). Page 6 3-1/2” 2-5/8” 1-1/2 OA FIGURE 3 Cut Off Pressure Tap Valve FIGURE 4 9-1/4

Louisville Tin and Stove 90N75A

Downloads : 0 Arquivo Tamanho: 210 kb    Fabricante : Louisville Tin and Stove  
Categoria : Eléctrico

WARNING: Do not attempt to change pressure settings without proper training and instruments. To do so may cause your floor furnace to malfunction resulting in property damage, bodily injury, or death. The following information is provided for use by a trained service technician with measuring instruments. Minimum Inlet Pressure, Natural Gas……………………………………………………. 4.5 Inches Water Column Minimum Inlet Pressure, Liquefied Petroleum (L.P.) Gas……………………………….. 11.0 Inches Water Column Maximum Inlet Pres





categorias