Log:

Hunter Fan Y8150

Downloads : 1 Arquivo Tamanho: 1 mb    Fabricante : Hunter Fan  
Categoria : Fans

BEDROOMS M22009 Ventilation Limit* Ventilation Standard 1 2 60% ASHRAE 62.2 100% 62-1999 Setting ventilation limit and ventilation standard. 68-0282—07 6 Y8150 FRESH AIR VENTILATION SYSTEM, W8150 FRESH AIR VENTILATION CONTROL Y8150 FRESH AIR VENTILATION SYSTEM, W8150 FRESH AIR VENTILATION CONTROL 1. Be sure power is turned on. 2. Set the Ventilation Standard on the control. 3. Set the bedrooms dial. 4. Set the area (sq ft) dial. 5. Set the airflow (cfm) dial. 6. Press the test button and observe

Hunter Fan WELLESLEY 82001

Downloads : 0 Arquivo Tamanho: 8 mb    Fabricante : Hunter Fan  
Categoria : Fans

C12EF Slide the mounting rails into brackets. Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. 5/81/25/81/2C13 C14 Mark position of screws by using holes as a template. 41941-01 3/29/2006 11 05-HF-012-EngS_3.29.06.indd 11 3/29/06 3:19:24 PM C17 C18 C19 C20 12 C15 C16 Drill a hole in the center of each outline. Insert screws, leaving space between the screw head and the joist. Screws are not provided. Attach the rails onto the screws. Tight

Hunter Fan W8150

Downloads : 2 Arquivo Tamanho: 1 mb    Fabricante : Hunter Fan  
Categoria : Fans

17 AUX Auxiliary (two terminals) 24 Vac dry contacts allow W8150 to control an auxiliary device, such as exhaust fan or HRV/ERV, with a call for ventilation. 18 DAMPER Damper (two terminals) 24 Vac powered contacts control fresh air damper. 19 XFMR C 24 Vac ventilation control common Supplies power to W8150 and damper from transformer provided. 20 XFMR R 24 Vac ventilation control power Supplies power to W8150 and damper from transformer provided. INSTALLATION A fresh air duct and damper must be

Hunter Fan W7345

Downloads : 0 Arquivo Tamanho: 631 kb    Fabricante : Hunter Fan  
Categoria : Fans

Mount the device in a location protected from rain, snow, and direct sunlight. The logic module mounts on the side of an M7215 Damper Motor or directly on a sheet metal duct or panel. NOTE: Refer to Figures 4 and 5 for representative locations of connected system devices. CAUTION Equipment Damage Hazard. Mounting screws longer than 5/8 in. can damage internal motor components. When mounting the module to an M7215 use only the included #6 5/8 in. thread-forming screw. MOUNTING DIRECTLY TO THE MOT

Hunter Fan W7340

Downloads : 1 Arquivo Tamanho: 631 kb    Fabricante : Hunter Fan  
Categoria : Fans

M22822 MODBUS EXHAUST AIR DISCHARGE AIR INDOOR FAN EXHAUST FAN M7215 MOTOR WITH W7345 ECONOMIZER LOGIC MODULE 1 1 1 Fig. 5. Representative Locations of Connected W7345 Economizer System Devices. 5 63-2569—04 W7340, W7345 COMMUNICATING ECONOMIZER LOGIC MODULES W7340, W7345 COMMUNICATING ECONOMIZER LOGIC MODULES WIRING 1. All wiring must comply with applicable local codes, ordinances and regulations. 2. Refer to Figures 6 and 7 for typical wiring diagrams. CAUTION 3. All inputs and outputs to the

Hunter Fan VENTURA BATH VENTILATOR FAN WITH LIGHT 81004

Downloads : 0 Arquivo Tamanho: 7 mb    Fabricante : Hunter Fan  
Categoria : Fans

If you have questions, contact the manufacturer at the phone number or address listed in the warranty. 2. Before installing, servicing, or cleaning the unit, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely attach a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by qualified person(s) in accord

Hunter Fan UH68ODK

Downloads : 11 Arquivo Tamanho: 1 mb    Fabricante : Hunter Fan  
Categoria : Eléctrico

Failure to observe fuel requirements could cause damage to the heater assembly and injury or death to personnel within or around the tent and the heater assembly. Always place fuel can in well-ventilated area as far away from open flames and other potential ignition sources as possible. Fuel spills shall be cleaned up in accordance with local requirements. Always switch heater to the OFF position and wait until the vent fan is off before refueling. EXPLOSION HAZARD FUEL LEAKS Do not operate heat

Hunter Fan UH68ODH

Downloads : 0 Arquivo Tamanho: 1 mb    Fabricante : Hunter Fan  
Categoria : Eléctrico

Preventative Maintenance Checks and Services (PMCS) Systematic, periodic PMCS are essential to ensure that the heater is ready for operation at all times. Description Ref. Para. Daily Monthly Semi Annually Annually Interval Fuel Line system 1.1 BDA Exhaust Stack 1.2 B Fuel Supply 1.3 X BD,9Hrs Electrical Connections 1.4 B Remote Control Panel 1.5 B PUDA 1.6 B Ducts 1.7 B Sediment Bowl 1.8 1000 Hrs Carburetor 1.9 500 Hrs Burner Head 1.9 X Igniter 1.10 X Fuel Pump 1.11 X Heat Exchanger 1.12 X Over

Hunter Fan SPA SELECT 90059

Downloads : 2 Arquivo Tamanho: 3 mb    Fabricante : Hunter Fan  
Categoria : receptor e amplificador

NO WARRANTY, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IS MADE IN RESPECT OF GLASS FIXTURES OR LIGHT BULBS OR THE FINISH ON ANY METAL PORTION OF THE BATH EXHAUST FAN. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES. THE DURATION OF ANY IMPLIED WARRANTY, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IN RESPECT TO ANY HUNTER FAN BATH EXHAUST FAN MOTOR OR OTHER FAN PART, I

Hunter Fan SPA SELECT 90051

Downloads : 1 Arquivo Tamanho: 3 mb    Fabricante : Hunter Fan  
Categoria : receptor e amplificador

41717-EngS_05.31.06.indd 10 5/31/06 3:53:32 PM D F E B16 D B14 A A A Green Black White Bare Copper B15 Ground B D D B17 0 G D B18 Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. Connect wiring from the motor to the wiring cover plate. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. 11 Connect the wiring. Connect wires as shown. H B19





categorias