Log:

Bacharach True Spot

Downloads : 4 Arquivo Tamanho: 30 kb    Fabricante : Bacharach  
Categoria : Alarme de incêndio

Too much smoke is one of the most common causes of excessive fuel usage and expensive service requirements. That is precisely why the smoke test is an indispensable part of any oil burner service job; and with the True Spot, an accurate smoke reading takes less than a minute. The True Spot smoke test method has long been recognized as the accepted standard for oil burner smoke tests. It is used by Underwriters' Laboratories in approval testing of oil burners; and it is the test method specified

Bacharach The Informant Dual Purpose Leak Detector

Downloads : 14 Arquivo Tamanho: 599 kb    Fabricante : Bacharach  
Categoria : Alarme de incêndio

The refrigerant sensor tip is finely tapered to 0.2" diameter - so you can get in between coils and fittings, gaining access to hard to reach areas. The Informant™ 2 leak detector features an audible indicator with a mute option coupled with sequential LEDs to monitor increasing concentrations of refrigerant or combustible gases. Dual bar graph displays offer visual confirmation no matter what position the instrument is in. And, a flashing light at the tip of the probe helps to visually define

Bacharach Stinger

Downloads : 13 Arquivo Tamanho: 8 mb    Fabricante : Bacharach  
Categoria : Aparelhos de ar condicionado

(0.13kg/min.) Liquid Recovery Rate: 3.53lbs./min. (1.60 kg/min.) Liquid Push / Pull: 12.28lbs./min. (5.58 kg/min.) Refrigerant134a Vapor Recovery Rate: 0.22lbs./min. (0.10 kg/min.) Liquid Recovery Rate: 2.66lbs./min. (1.21 kg/min.) Liquid Push / Pull: 10.96 lbs./min. (4.98 kg/min.) Refrigerant410aVapor Recovery Rate: 0.22lbs./min. (0.10 kg/min.) Liquid Recovery Rate: 3.00lbs./min. (1.37 kg/min.) Liquid Push / Pull: 14.58lbs./min. (6.63 kg/min.) Auto80%TankOptional Shut-OffWeight24 lbs. (11 kg) S

Bacharach Snifit 40

Downloads : 0 Arquivo Tamanho: 49 kb    Fabricante : Bacharach  
Categoria : Alarme de incêndio

This continuous operating instrument quickly and accurately measures levels of CO between 0 and 1,999 ppm. Weighing just 8 ounces, the Snifit analyzers are light as a feather and small enough to fit in your shirt pocket or hold in the palm of your hand. With one button operation, the Snifit analyzers are simple to use. Special design features such as a zero adjustment control and a fast response sensor specific to CO gas make the Snifit analyzers perfect for measuring low levels of CO. 29 App

Bacharach SF6

Downloads : 2 Arquivo Tamanho: 3 mb    Fabricante : Bacharach  
Categoria : Alarme de incêndio

(8.2 kg) Warranty Two year full warranty on instrument The H25-IR instrument, along with its probe type and hose length, is ordered by specifying 3 codes. The codes Ordering Information ProbesStandard Probe, LED & Button Contains a button that can be configured to either zero the unit or switch between the instrument’s search and measure modes. Also contains an LED that provides visual feedback. The LED can be configured to blink with increasing frequency as the measured leak rate increases or l

Bacharach RDM800

Downloads : 2 Arquivo Tamanho: 652 kb    Fabricante : Bacharach  
Categoria : Alarme de incêndio

Text Box: THERE ARE 4 STEPS: Text Box: U HOW TO: SILENCE ALARMS on the HGM300 Text Box: STEP #2: PRESS THIS BUTTON, which will take you to the “ALARM SUMMARY SCREEN”. Text Box: STEP #3: Each alarm must be acknowledged separately. To do that PRESS THIS BUTTON and go to the “ALARM DETAIL SCREEN”. Text Box: STEP #4: PRESS THIS BUTTON TO ACKNOWLEDGE THIS ALARM. ANY OTHER ALARMS WILL HAVE TO BE DEALT WITH IN THIS WAY TO SHUT OFF THE ALARM HORN! IF REFRIGERANT GAS IS STILL LEAKING INTO THIS ZONE THE A

Bacharach R-600a

Downloads : 1 Arquivo Tamanho: 3 mb    Fabricante : Bacharach  
Categoria : Alarme de incêndio

The instrument can be used to locate and quantify leaks as well as log and totalize the entire group of leaks in a system to ensure quality assurance compliance. The unit is capable of detecting 29 of the most commonly used refrigerants and halogen gas compounds. Additional gas-specific models are available for R-600a and SF6. Industrial Refrigerant Leak Detector Infrared Technology Fewer False Alarms Fast Response Time • Utilizes Infrared Technology for Detection ensures long sensor life and hi

Bacharach Portable Combustion Analyzer 24-9351

Downloads : 3 Arquivo Tamanho: 474 kb    Fabricante : Bacharach  
Categoria : Alarme de incêndio

The following message is displayed while the analyzer is being purged. . As soon as the CO level falls below 100 ppm, the pump turns off and the analyzer starts its normal 5 second turn-off sequence. To abort the purging process and immediately start the analyzer’s turn-off sequence, press the key. NOTE: Turning the analyzer off initiates a 5-second delay, during which time the unit can be turned on again without any warmup time. You can turn the analyzer back on during this 5-second delay by p

Bacharach PE120CA

Downloads : 0 Arquivo Tamanho: 575 kb    Fabricante : Bacharach  
Categoria : Alarme de incêndio

The interconnect system should not exceed the NFPA interconnect limit of 12 smoke alarms and/or 18 alarms total (smoke, heat, carbon monoxide, etc.) With 18 alarms interconnected, it is still possible to interconnect up to a total of 6 remote signaling devices and/or relay modules. I M P O R TA N T: Kidde alarms and accessories CAN ONLY BE interconnected with other Kidde alarms and accessories as well as specified brands and models of interconnect compatible alarms. Connection of Kidde products

Bacharach PCA 2 24-9448

Downloads : 0 Arquivo Tamanho: 5 mb    Fabricante : Bacharach  
Categoria : Alarme de incêndio

All other trademarks, trade names, service marks and logos referenced herein belong to their respective companies. A Instruction 24-9448 Contents Contents 1 Introduction..................................1-1 1.1 PCA 2 General Description...............................1-1 1.2 Sales Combo & Model Configurations......................1-2 1.3 Features & Benefits....................................1-4 1.4 Operational Overview...................................1-5 1.5 Connector Descriptions..