Keep this manual for future reference. Muchase gracias por comprar un aire acondicionado Admiral®. Lea atentamente el “Manual de Uso y Mantenimiento” antes de instalar y utilizar este producto. Conserve este manual para consultarlo en el futuro. For Service Call 1 877 465 3566 Para obtener servicio tecnico, llame al 1 877 465 3566 ROOM AIR CONDITIONER Use and Care Manual AIRE ACONDICIONADO PARA HABITACIONES Manual de Uso y Mantenimiento WAC 5 6 8 USER MAN final 3/2/05 12:23 PM Page 1 WAC 5 6 8 U
More frequent cleaning may be necessary depending on outdoor and indoor air quality. 3. Use drapes, curtains, or shades to keep direct sunlight from heating your room, but DO NOT obstruct the air conditioner. Allow air to circulate around the unit without obstructions. 4. Start your air conditioner before outdoor air becomes hot/cold and uncomfortable. This avoids an initial period of discomfort while the unit is cooling or heating off the room. 5. When outdoor temperature is cool enough, use HI
When outdoor temperature is approximately 65 F or below, frost may form when unit is in cooling mode. Switch unit to FAN (only) operation until frost melts. Remove and clean filter. PROBLEM POSSIBLE CAUSE SUGGESTED SOLUTION Air conditioner will not operate Inefficient or no cooling Noisy unit Odors Water dripping outside Water dripping inside Ice or frost build-up Low outside temperature. Unit air filter is dirty. Unit is not properly angled to allow water to drain outside. Unit must be installe
However, the fan motor will continue to operate after the compressor (cooling cycle) is completed. Fresh Air Ventilation is usually kept in the closed position. Use only when clearing smoke and/or odors from the room. Pull to open. p g Fig. 15 Mechanical control model Thermostat knob Mode knob Fig. 16 Fresh Air Vent Lever F H R FAN SPEED MODEOFFON/ TIMER Airconditioner WAIT THREE MINUTES BEFORE RESTARTING LOW FAN MED FAN HIGH FAN OFF HIGH COOL MED COOL LOW COOL 1 3 5 7 9 CO LER O 1 3 13 OPERATIN
. . . . . .14 I.NDICE Page Introduccion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Identificacion de las Piezas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Especificaciones Electricas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Consejos Antes dela Instalacion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 Instrucciones de Instalacion . . . . . . . . . .
4. Remove solution hoses from fittings in pump. 5. Remove the (2) screws that fasten the pump to the frame. 6. Reverse process to install pump. ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM THE FOLLOWING REPAIRS. BELT REPLACEMENT 1. Turn off all switches and unplug machine. 2. Remove recovery tank and brush. 3. Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the frame. 4. Loosen the (4) screws that hold the brush motor in place a
Maximum air circulation and cooling occur when in the closed position. ON/OFF button The air conditioner will be started when it is energized or will be stopped when it is in operation, if you press this button. MODE button Each time MODE button is pressed, the operation mode is changed in sequence: COOLING FAN ONLY ENERGY SAVING COOLING NOTE: After setting the mode, allow 3 minutes before switching to another mode. FAN SPEED button Used to select fan speed in sequence auto, low, medium and high
If the leveling screws are distanced too far away from the wall to provide stability, it may be necessary for you to fill this area with a solid piece of wood. See (Fig. 8). Fig. 5 Bracket Assembly Bracket Bolts Leveling Screw V-slot 90 Angle Support Brackets (TOP VIEW) Center Window sill V-slot (2) 3/4" screws per bracket Bracket Assembly Leveling Screw Outer Wall Construction 3/16" Maximum B. Measure the inside window sill width and find the center as shown in (Fig. 6). Align the V-slot in eac
Please read this "Use and Care Manual" carefully before installing and using this appliance. Keep this manual for future reference. Muchase gracias por comprar un aire acondicionado Admirar Lea atentamente el “Manual de Uso y Mantenim ento” antes de instalar y utilizar este producto. Conserve este manual para consultarlo en el futuro. For Service Cali 1 877 465 3566 Para obtener servicio técnico, llame al 1 877 465 3566 TABLE OF CONTENTS Page Air Conditioner Safety.........................
—SAVE THESE INSTRUCTIONS — 4 WAC 5 6 8 USER MAN final 3/2/05 12:23 PM Page 7 INSTALLATION REQUIREMENTS • The portable air conditioner should be connected to a 115 V, 60 Hz, 15- or 20-amp fused 3-prong grounded outlet. • The use of a time-delay fuse or time-delay circuit breaker is recommended. • All wiring must comply with local and national electrical codes and be installed by a qualified electrician. If you have any questions, contact a qualified electrician. Electrical Requirements ELECTRIC S