Log:

Husky & HD349000

Downloads : 3 Arquivo Tamanho: 2 mb    Fabricante : Husky  
Categoria : Pistola de pregos

© 2007 Nailer Components And Specifications HD219000 HD289000 • REQUIRES (SCFM with 16 nails 4.1 4.1 per minute @ 90 psi) • AIR INLET 1/4 inch NPT 1/4inch NPT • NAIL LENGTH 2 inch 2 inch RANGE to 31.2 inch to 31.2 inch • NAIL SHANK 0.113 inch to 0.113 inch to RANGE 0.131 inch 0.131 inch • MAGAZINE CAPACITY 60-75 75-105 • WEIGHT 8 lbs. 5 oz. 8 lbs. 15 oz. • LENGTH 19.5 inch 21.75 inch • HEIGHT 15 inch 15 inch • MAX PRESSURE 120 psi 120 psi • PRESSURE RANGE 70 - 120 psi 70 - 120 psi HD349000 4.1 1

Husky 1550 PSL

Downloads : 13 Arquivo Tamanho: 4 mb    Fabricante : Husky  
Categoria : Equipamento de lavagem

WARNING: Prevent water from penetrating the vents of the pressure washer to minimize the risk of damage to the machine and to reduce the risk of shock to the operator. WARNING 7.0 SERVICING A DOUBLE- INSULATED APPLIANCE In a double-insulated product, two systems of insulation are provided instead of grounding. No grounding means is provided on a double-insulated product, nor should a means for grounding be added to the pressure washer. Servicing a double-insulated product requires extreme care a

Husky 1650 PSL

Downloads : 11 Arquivo Tamanho: 4 mb    Fabricante : Husky  
Categoria : Equipamento de lavagem

Husky 16628

Downloads : 5 Arquivo Tamanho: 93 kb    Fabricante : Husky  
Categoria : Interior

Important! Please follow these instructions. This kit may be different from the one specified in instruction booklet. COMBINATION 8X8 and 10X8 FLOOR KIT This floor kit will build either the 10’ wide or 8’ wide x 7’ 8-5/8” deep floor size FOR MARCO SERIES, SOLAR SHED AND MWP IMPERIAL ONLY This floor kit is for 10’ x 7’ 8-5/8” and 8’ x 7’ 8-5/8” buildings. Please refer to the appropriate pages of this instruction manual to build the floor size needed. If constructing an 8X8 storage building, you w

Husky 1750 PSL

Downloads : 24 Arquivo Tamanho: 4 mb    Fabricante : Husky  
Categoria : Equipamento de lavagem

Register your new HUSKYPOWERWASHER at the web site. For ease of reference, please record now the serial number and the date of purchase in the space provided below. Serial Number: ............................................................................... Date of Purchase: / /200 2 HUSKYPOWERWASHER Votre numero de modele est : Husky 1750C (1750 PSI) IMPORTANT Enregistrez votre numero de serie ci-dessous: Cher client, chere cliente, les renseignements fournis ci-dessous sont essentiels en cas

Husky 1750 US

Downloads : 12 Arquivo Tamanho: 3 mb    Fabricante : Husky  
Categoria : Equipamento de lavagem

Husky 1800 Series

Downloads : 8 Arquivo Tamanho: 518 kb    Fabricante : Husky  
Categoria : Equipamento de lavagem

Please leave this manual with the pump owner after the installation is complete. Copyright 1999 by Gasboy International, Inc. All rights reserved. The information in this document is confidential and proprietary. No further disclosure shall be made without permission from Gasboy International, Inc. Gasboy International, Inc. believes that the information in this document is accurate and reliable. However, we assume no responsibility for its use, nor for any infringements of patents or other righ

Husky 23-SP HDN16450AV

Downloads : 0 Arquivo Tamanho: 2 mb    Fabricante : Husky  
Categoria : Pistola de pregos

Caution indicates a potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury. Notice indicates important information, that if not followed, may cause damage to equipment. NOTE: Information that requires special attention. General Safety Information CALIFORNIA PROPOSITION 65 This product or its power cord may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling. You can creat

Husky 70 Series

Downloads : 8 Arquivo Tamanho: 518 kb    Fabricante : Husky  
Categoria : Equipamento de lavagem

To keep your pump running at maximum efficiency, GASBOY recommends a periodic inspection at least twice a year. . Remove Water from Tank. After every fill-up, check your tanks for water. Water can accumulate in both underground and aboveground storage tanks due to condensation or defective fill openings that are not properly protected with watertight covers. Remove any water with a sump pump to forestall serious damage to equipment. Water, sediment, and other foreign matter that accumulates in t

Husky A05051

Downloads : 7 Arquivo Tamanho: 564 kb    Fabricante : Husky  
Categoria : equipamento de bombagem

Y1010 ESPANOL . . . . . . . . . . . . . . . .21-39 FRANCAIS . . . . . . . . . . . . .40-60 Questions? 1-800-888-2468 Part No. A05051 Rev. 0 07/26/04 READ AND SAVE THESE INSTRUCTIONS SAFETY GUIDELINES - DEFINITIONS This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the symbols below. Please read the manual and pay attention to these s